10demerits
INDIGO AT BEREWICK
3125 FURR CT, Charlotte, NC 28273
Year-Round Swimming Pool · NC permit/State ID 2060530673
Latest result10 demerits
Last inspectedSep 8, 2026
Inspections on record9
On record sinceAug 29, 2022
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 29, 2022Lower is betterSep 8, 2026
Inspections & violations
Sep 8, 2026 10 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Pedro.
No night swimming.
NOTES: 1) Barrier is area outside of the backflows and also HVAC units due to foothold issues with units 2) Double doors from clubhouse must remain inoperable
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
Observed chlorine measuring less than 1.0 ppm.
CPO manually adjusted chlorine levels on control valve and EHS observed chlorine had risen to 1.5 ppm.
No permit action.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed one out of four weirs missing.
Replace missing weir.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed skimmers dull of debris, plastic bottle, and other misc items.
CPO dumped out skimmers during the inspection.
Mar 2, 2026 2 demerits · 1 violation
Inspector comments: Conducted inspection with CPO. Pool remains on A status and in good standing.
NOTE: BARRIER IS AREA OUTSIDE OF THE BACKFLOWS AND ALSO HVAC UNITS DUE TO FOOTHOLD ISSUES WITH UNITS. PERMIT RESTRICTION: 1) DOUBLE DOORS FROM CLUBHOUSE MUST REMAIN INOPERABLE.
Const. Date: 8/1/2022 Rope Length: 45' Night Swim?: No
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Liquid chemicals stored in pump room.
Sep 17, 2025 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO Pedro. All items in compliance. Pool remains in good standing and on A status.
No night swimming.
Const. Date: 8/1/2022
Rope Length: 45'
NOTE: BARRIER IS AREA
OUTSIDE OF THE
BACKFLOWS AND ALSO
HVAC UNITS DUE TO
FOOTHOLD ISSUES WITH
UNITS.
PERMIT
RESTRICTION: 1) DOUBLE
DOORS FROM
CLUBHOUSE MUST
REMAIN INOPERABLE
No violations were recorded for this inspection.
Mar 26, 2025 6 demerits · 1 violation
Inspector comments: Conducted inspection with CPO Pedro. All items corrected by end of inspection. Pool remains in good standing and on A status.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buy rope too long. Operator corrected to the approved 45’. No permit action.
Sep 23, 2024 12 demerits · 3 violations
Inspector comments: Inspection conducted with operator Pedro Heredia. Intent to suspend issued for missing records. Pool has 30 days to correct or permit may be suspended. Call or text EHS Devon Moeller when corrected. 7049981122
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Records missing for all of September. Daily records must be maintained. Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Provide at least one handrail on steps. Left step handrail loose.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted pool callback number incorrect. Operator corrected by posting correct number. No permit action.
Feb 7, 2024 6 demerits · 2 violations
Inspector comments: Brandon Wilson present during inspection.
Inspection led by Troy Kling under supervision of Devon Moeller.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. EHS observed expired reagents in test kit. EHS recommends replacing expired reagents. No permit action.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Few records missing in January 2024. Ensure daily records are maintained. No permit action.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in mens’ or womens’ restrooms.
Aug 14, 2023 16 demerits · 3 violations
Inspector comments: Inspection conducted with operator, Brandon. Immediate suspension of permit issued due to 0 ppm chlorine in pool and Kings III emergency phone system nable to be forwarded to local Charlotte 911. Pool closed with signs posted. Once pool chemistry is corrected and emergency phone is operating properly, call Hope McIntosh to schedule a re-visit.
Night swimming is not approved.
Note: Community name change from Madison Place Apartments to Indigo At Berewick.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. 0 ppm cl in pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris buildup in skimmer baskets. Operator cleaned during inspeciton.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III emergency notification system not forwarding calls to local charlotte 911 dispatch. Phone system appears hung in loop with continuous ringing - unable to bypass or exit to communicate further.
Feb 22, 2023 14 demerits · 3 violations
Inspector comments: Inspection conducted with Pedro Heredia. Immediate suspension of permit issued due to inability of Kings III emergency phone/box to route calls to 911. Pool closed and signs posted during inspection. Pool must remain closed until issue resolved and verified by Mecklenburg County Public Health. Once corrected, call Hope McIntosh at 980-229-7549 for a return visit.
Once permit is re-instated, a 30 day intent to suspend the permit may be issued if the following items remain non-compliant:
Flow meter not operating
Record keeping incomplete/missing.
Night swimming not permitted at this time.
Note: door leading from pool deck to restrooms not responding to fob - will not open from pool deck. Correct to ensure access to restrooms without having to leave pool area and access through other side of club house.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records avialble for months of Sept, Oct, Nov, or Dec 2022. January records not completed for several days and then records indicate 0 for all chemical readings until end of monty. Missing records for Feb 17, 23. Intent to suspend item
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III box connects to Kings III operator but operator unable to route calls to 911. Recording stating that there is a programming issued can be heard. Phone number posted at the emergency phone is actually apartment office phone and not pool side phone. Phone number provided by Kings III operator 434-304-5569 rings back to box correctly.
Immediate suspension of permit issued today due to emergency phone box not capable of routing calls to 911 and not having proper call back number posted by emergency phone.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Digital flow meter reading flow rate of 0 although flow through system is present. Repair.
Intent to suspend item.
Aug 29, 2022 0 demerits · 0 violations
Inspector comments: Observed no non-compliant conditions
Rick Shultz present during inspection.
permit issued
No violations were recorded for this inspection.