‹ Back to search

16demerits

AVANT AT STEELE CREEK II

12918 WINTER HAZEL RD, Charlotte, NC 28278
Year-Round Swimming Pool · NC permit/State ID 2060530694
Latest result16 demerits
Last inspectedAug 28, 2025
Inspections on record6
On record sinceMay 26, 2023

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02040 May 26, 2023: 0Sep 7, 2023: 40May 24, 2024: 16Sep 10, 2024: 10Mar 24, 2025: 16Aug 28, 2025: 16
May 26, 2023Lower is betterAug 28, 2025

Inspections & violations

Aug 28, 2025 16 demerits · 6 violations
Inspector comments: Conducted inspection with operator Larry. Intent to suspend issued for gate handles foothold, gate not self latching, and inoperable flow meter. Items must be corrected within 30 days or pool permit may be suspended. Contact EHS Devon when corrected. 7049981122 No night swimming. Construction date: 3/1/2008 Rope length 45’ Permit restriction: Pump must remain set at 3450 RPM to meet turnover of 123 gpm.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end caps on both pool ladders.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a)(2) Openings in the barrier shall not allow passage of a four inch diameter sphere and shall provide no external handholds or footholds. New gate handles protrude more than 2in and are 38” from ground creating a foothold. Correct by raising handle or installing slanted piece of metal above foothold. Intent to suspend item. .2537(b) All gates and doors shall be self-closing, self-latching. Main gate not self latching. Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter stuck at bottom. Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bags of dry chemicals on floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals in pump room. Move to a designated chemical storage room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms. No toilet paper available. Stock restrooms with toilet paper

View this inspection on the county portal ›

Mar 24, 2025 16 demerits · 5 violations
Inspector comments: Conducted inspection with CPO Larry. Pool remains in good standing and on A status.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records present for December, January, or February. Operator said the pool was closed. Daily records have been kept for all of March. Ensure records reflect closure when the pool is closed. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end caps on both pool ladders.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Main gate not self latching. Operator corrected. No permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter stuck. Operator corrected by backwashing. No permit action.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not operational.

View this inspection on the county portal ›

Sep 10, 2024 10 demerits · 3 violations
Inspector comments: Performed inspection with CPO Randy Medrano. Pool to remain on A status.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. A couple August daily records missing. Ensure consistent daily record keeping. No permit action.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. All four weirs missing. CPO replaced and corrected. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end caps on both pool ladders.

View this inspection on the county portal ›

May 24, 2024 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Randy. Intent to suspend issued for out of compliance depth marker distanced. Item must be corrected by permit expiration or pool will need to close until corrected. Call Devon when corrected 7049981122.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Test kit reagents expired. Replace with in date reagents. No permit action.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Pool has been re-surfaced. During this process some depth markers and no diving tiles have been moved. Distance between 4 1/2 ft depth markers t26’6”. distance between each of the 3 1/2 ft depth markers on far end of pool 26’4” and 27’. Maximum distance allowed between depth should be no more than 25’. Correct. *Intent to suspend item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end caps on ladder on left side of pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope at 45’. Operator replaced rope and corrected to 45’.

View this inspection on the county portal ›

Sep 7, 2023 40 demerits · 10 violations
Inspector comments: Inspection conducted with operator Randy. Immediate suspension of permit issued due to pool Ph and removal of equalizers and change of drain covers without re-submittal of required PDSC. Submit PDSC with current information on equalizer removal and drain cover information to pdsc@mecknc.gov. Once PDSC is approved and pool chemistry is in compliance, call Hope McIntosh at 980-229-7549 to schedule a return visit. At that time other permit items noted in the inspection will be re-evaluated and if not in compliance a 30 day intent to suspend may be issued. Pool must remain closed with signs posted for no swimming until permit is re-instated.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool water pH at 8.0. *immediate suspension item
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. During re-plaster equalizer lines have been disabled and covers removed and main drain covers have been replaced. A new PDSC form must be submitted to the department for approval. *immediate suspension item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Leaf litter and debris in pool bottom
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Leaf litter and debris in skimmers
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Pool has been re-surfaced. During this process some depth markers and no diving tiles have been moved. Distance between 4 1/2 ft depth markers t26’6”. distance between each of the 3 1/2 ft depth markers on far end of pool 26’4” and 27’. Maximum distance allowed between depth should be no more than 25’. Correct. *permit item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end caps on ladder on left side of pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope at 44’. Operator corrected to 45’.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gated entrance to left of pool currently pad-locked shut. EHS unable to determine if gate self-closes and latches. Pad lock is not permanently disabling gate. Gate must be accessible for testing to ensure self-closure and self-latching or it must be permanently fixed shut (similar to other gate on right side of pool). EHS recommends ensuring permanently fixing this gate shut does not violate other agency codes (like fire code) prior to permanently modifying the gate. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bags of dry chemicals on floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. .2526(l) Provide toilet paper and dispensers in restrooms. .2526(m) Keep restrooms and fixtures clean and in good repair. Both restrooms in need of cleaning. No soap available in either restroom. No toilet paper available in womens restroom.

View this inspection on the county portal ›

May 26, 2023 0 demerits · 0 violations
Inspector comments: Kings 3 box initially connected to a national dispatch service, through this service i was connected to local. On second attempt i was connected directly to local dispatch by operator by request. No violations noted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “AVANT AT STEELE CREEK II” or State ID 2060530694). Inspection type (routine vs. follow-up) is not published in the county's data.