‹ Back to search

10demerits

LINK APARTMENTS MINT STREET

1200 S MINT ST, Charlotte, NC 28208
Year-Round Swimming Pool · NC permit/State ID 2060530700
Latest result10 demerits
Last inspectedMay 26, 2026
Inspections on record7
On record sinceMay 3, 2023

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 May 3, 2023: 0Oct 24, 2023: 4Mar 13, 2024: 0Oct 10, 2024: 10Apr 10, 2025: 6Sep 11, 2025: 0May 26, 2026: 10
May 3, 2023Lower is betterMay 26, 2026

Inspections & violations

May 26, 2026 10 demerits · 2 violations
Inspector comments: POOL WAS APPROVED FOR NIGHT SWIMMING. C. ELMORE WILL PERFORM NIGHT SWIMMING EVALUATION BEFORE THE END OF THIS YEAR. ENSURE PROPER LIGHTING FOR NIGHT TIME USE. PERMIT RESTRICTIONS: Requires 5% flow meter for 2026 for feature. Permit Restrictions: 1) Filtration flow meter shall remain operable. Flow required at 66 gpm to 80 gpm to meet turnover and flow restrition of the number of returns. 3) Sump pump or other means required to drain the pool. 4) Feature pump required set at 1500 gpm or less. Flow meter must remain operable. Flow required less than 145 gpm due to drain cover flow restriction. Suction Hazard. 5) Feature pump system cannot be turned on until the new 5% flow meter installation and compliance is verified by the Health Department. Note: Pool is approved with salt as primary chlorination. MAIN DRAIN COVERS EXPIRE 3/14/2028 POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed the emergency phone number posted to be 980-236-8405 which was determined to be incorrect. The correct number (980-236-8705) was posted. -CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
The feature pump system is operating on a reduced flow requirement and must have a 5% accurate flow meter installed. The system is currently turned off. The system cannot be turned back on until after a new flow meter is installed and the flow is verified to be in compliance with the restriction. (1,500 RPM on the motor with a flow less than 145 GPM). Contact C. Elmore when this is corrected. (704-507-6814). C. Elmore will follow-up to ensure correction.

View this inspection on the county portal ›

Sep 11, 2025 0 demerits · 0 violations
Inspector comments: Main drain covers expire 3/14/2028. Pool is approved for night swimming, lights were observed to work during the inspection. No violations noted. PERMIT RESTRICTION: 1) FIRE PIT SHALL NOT UTILIZE GLASS. GLASS SHALL BE TEMPERED. 2) PORTABLE VACUUM REQUIRED. 3) SUMP PUMP REQUIRED TO DRAIN POOL IF NEEDED. 4) FLOW METER MUST REMAIN OPERABLE. FLOW RANGE MUST MEET TURNOVER AT 66 GPM NOT TO EXCEED 80 GPM DUE TO RETURN NUMBER RESTRICTION. 5) FEATURE PUMP MUST REMAIN AT 1500 GPM DUE TO DESIGN SPECIFICATIONS OF SYSTEM (PLAN APPROVAL)Note: Pool is approved with salt as primary Chlorination. Pumps are both the same model 022056 Intelliflo XF VSF, verified on the PEHS PDSC excel spreadsheet.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2025 6 demerits · 1 violation
Inspector comments: Ensure proper records are kept. CPO must attend the pool daily, records must be properly kept every day the pool is open. Main drain covers expire 3/14/2028. Pool is approved for night swimming, lights were observed to work during the inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. 8.3 pH was noted upon arrival, pH was corrected to 7.7. CDI. Salt system may be the cause of elevated pH, this is a common Situation in salt system pool and must be managed to keep pH in the proper range.

View this inspection on the county portal ›

Oct 10, 2024 10 demerits · 2 violations
Inspector comments: Observed pool lights and deck lights operational for night swimming approval. Pool is night swimming approved.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Observed gaps in the log record. Keep all daily and weekly records properly. No Permit Action taken.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed hook to be on a collapsible pole. The pole was also less than 12 feet long. Hook was moved to proper pole and reattached.

View this inspection on the county portal ›

Mar 13, 2024 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. POOL AND DECK LIGHTING WERE CHECKED AND FOUND TO BE OPERATING NORMALLY.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 24, 2023 4 demerits · 1 violation
Inspector comments: OBSERVED TEMPERED GLASS IN FIRE PIT. OBSERVED PUMPS TO HAVE 022056 ON THE PUMP DATA DECAL. THE PSDC FORMS SHOW A 022059 MODEL NUMBER, BUT THE PUMP CURVES FOR A 022056. C. ELMORE BELIEVES THIS IS A TYPOGRAPHICAL ERROR AND THAT 022056 IS THE INTENDED MODEL NUMBER. OBSERVED PHONE TO NOT CALL BACK WITH A VERIZON CELL PHONE, BUT TO WORK WITH AN AT&T PHONE.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed missing daily pool records, during weekends, for several months. 30 day ITS issued to verify proper record keeping.

View this inspection on the county portal ›

May 3, 2023 0 demerits · 0 violations
Inspector comments: Observed no non-compliant conditions. Permit issued Facility requested night swimming, to be completed 5/9

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LINK APARTMENTS MINT STREET” or State ID 2060530700). Inspection type (routine vs. follow-up) is not published in the county's data.