Aug 19, 2026 20 demerits · 6 violations
Inspector comments: Permit condition that flow is required at 143-220 GPM.
Permit condition that feature pump be set at no more than 3110 RPM. Observed at 3450 RPM at start of inspection, adjusted to 3110.
Note:
EHS recommends that the operator checks and corrects the accuracy of the flow meter.
EHS notes that the Cyanuric Acid was read approximately 180PPM. However chlorine level was 7.5. Per State guidance CA at 180 requires minimum of 4 CL.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
Observed incorrect CA readings on the facilities weekly recordings.
After speaking with the CPO EHS established that the CPO was correctly measuring the CA, however he was reading the test kit incorrectly.
-CDI- EHS coached the CPO on proper reading of CA testing. CPO understood.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537b(9) Underwater light niches shall be maintained or covered so as not to present a potential hazard to bathers.
Observed underwater light niche protruding from the wall.
-CDI- CPO fastened the light niche back into the wall.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed 2 out of 7 Weirs missing in the pool. Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris present in several skimmer baskets.
-CDI- CPO cleared debris of skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed caps missing on ladder edges. Ensure repaired or replaced so as not to damaged pool walls.
-CDI- caps were added by CPO
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Observed door into rear entry of the pool not self closing/self latching.
-CDI- CPO adjusted closure arm to ensure that door was self closing/self latching.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
Observed puddling of water in the pump room.
Ensure that pump room is free from standing water and dry.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed spilled white powder chemical present on the floor in the chemical room. Ensure chemical is cleaned up.
Mar 30, 2026 22 demerits · 6 violations
Inspector comments: Permit condition that flow is required at 143-220 GPM.
Permit condition that feature pump be set at no more than 3110 RPM. Observed at 3450 RPM at start of inspection, adjusted to 3110 prior to verifying 170 GPM on flow meter.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH maintained at 8. Corrected to 7.7 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records not maintained weekly for cyanuric acid and total alkalinity. Corrective action missing for PH being maintained at 8.
EHS discussed PH range needing to be 7.2-7.8. PH corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. End caps missing on one pool ladder.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. One “Warning- No Life Guard on duty” signage blocked by shrubbery and one not permanently affixed. CPO corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not functioning properly during inspection. Flow meter corrected to reflect correct GPM of 170 at 3110 RPMs.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water found in pump room due to small leak by pump basket adjacent to drain.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Soda ash stored directly on floor.
Nov 10, 2025 28 demerits · 7 violations
Inspector comments: Inspection conducted with inspector Rusi Woo and CPO Theo Hancock.
Permit condition that flow is required at 143-220 GPM. Verified at 155 GPM.
Permit condition that feature pump be set at no more than 3110 RPM. Observed at 1550 GPM.
New pool filtration pump installed. Pentair Intellifo XF VSF 022056. Like for like change. Does not need in-field plan review, does need passing electrical inspection.
Checked with office, failed electrical inspection for GFCI on 6/30/2025.
Immediate suspension issued
3)
Contact Will Harrison
#3 · Water quality: pool water pH −6
PH 8.0. .2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on log sheet for temperature checks. Spotty total alkalinity and cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing one endcap. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw ropes 44 feet long for ring buoys. .2530(a) Provide USCG approved ring buoy with attached 48 foot throw rope at least 1/4 inches in diameter. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Heater to pool installed outside the pump room. Panel is unlocked. .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items stored by pumps and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Bag of soda ash on the floor in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Feb 4, 2025 26 demerits · 6 violations
Inspector comments: Inspection conducted with maintenance staff Theo Hancock.
Outer rope on both ring buoys fraying. Recommend replacing with new US Coast Guard approved ring buoys.
Observed feature pump set at 1550 RPM.
Permit condition that flow meter must remain operable at 143 to 220 GPM to meet minimum turnover and flow restriction for the number of returns. Observed at 135 GPM today.
Immediate suspension issued
2)
Contact Will Harrison (704) 754-2130 for re-inspection once issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Operator able to adjust up to 0.5 ppm. - Immediate suspension item.
#3 · Water quality: pool water pH −6
PH > 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.7.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records since mid-December. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
Alex is no longer the CPO for this pool. Provide updated CPO certification. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#18 · Premises: lifeguards present or warning signs posted −4
Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Intent to suspend item.
Safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Intent to suspend item.
Aug 28, 2024 6 demerits · 2 violations
Inspector comments: Inspection conducted with maintenance staff Jay Harbin.
Outer rope on both ring buoys fraying. Recommend replacing with new US Coast Guard approved ring buoys.
Observed feature pump set at 1550 RPM.
Outdoor heated pool. Heater off at the time of inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing. .2518(k) Replace missing weirs.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Old equipment stored beside valves and piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Leak at spa filter. .2533(d) Pump room floor shall be kept dry and free of standing water.
Mar 25, 2024 20 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Alexis Rosas.
Pool heater added after pool was built. Verified electrical permit E4469507 passed inspection 8-10-2023. Mechanical permit M4464391 passed 8-22-2023.
Heater off at time of inspection.
Intent to suspend issued
5)
18)
24)
#3 · Water quality: pool water pH −6
PH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records spotty. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity.
#18 · Premises: lifeguards present or warning signs posted −4
Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Intent to suspend item.
Safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Heater to pool installed outside the pump room. Accessible to the public. .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. - Intent to suspend item.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Piping for pool heater not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
Jul 25, 2023 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Alexis Rosas.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records spotty. Inconsistent total alkalinity and cyanuric acid checks. No pool water maintenance activities. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir floating in the skimmer basket. .2518(k) Replace missing weirs. - Corrected.
Skimmers baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder < 3” from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Ladder loose. .2521 Install ladders per manufacturer instructions.
May 26, 2023 0 demerits · 0 violations
Inspector comments: Onsite visit to pool for return construction and operating permit inspection.
Construction final passed. Permit issued for no night swimming.
Max Depth 5 ft.; Pool Width 32 ft.; Rope Length 48 ft.
Permit Restrictions:
1)Filtration pump flow meter must remain operable. Flow required at 143 - 220 gpm to meet turnover and flow restriction for number of returns.
2)Feature pump shall be set at 3110 RPM due to flow restriction of return piping.
3)Pool is not approved for salt as primary chlorination.
4)No deck furniture behind planters so that at least 5 ft. clearance around decorative feature.
5) Sweeps required on underside of gates at two back entrances to maintain 2" or less.
Filtration Pentair IntellifloXF VSF, 022056 pump with (2) Lawson MLD-SG-0909 drain covers, VGB-2008. EQ lines plugged in skimmer.
Feature Pentair Intelliflo VSF, 3 hp 011056 with (2) Lawson MLD-SG-0909 drain covers, VGB-2008.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “TAYLOR FARMS LUXURY APARTMENT HOMES” or State ID 2060530706). Inspection type (routine vs. follow-up) is not published in the county's data.