14demerits
LINDEN APARTMENTS, THE
605 JETTON ST, Davidson, NC 28036
Year-Round Swimming Pool · NC permit/State ID 2060530711
Latest result14 demerits
Last inspectedAug 11, 2026
Inspections on record8
On record sinceJun 2, 2023
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 2, 2023Lower is betterAug 11, 2026
Inspections & violations
Aug 11, 2026 14 demerits · 4 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING.
MAIN DRAIN COVERS EXPIRE 10/30/2028
INTENT TO SUSPEND ISSUED FOR THE GATES AND THE BATHROOM SINKS. DEADLINE FOR CORRECTION IS 9/10/2026. FAILURE TO CORRECT THE ISSUED PRIOR TO THAT DATE WILL RESULT IN CLOSURE OF THE POOL.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable.
2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
Observed gaps in the log book records. Keep proper records for every day the pool is open.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed the access gates to self-close, but not reliably self-latch. They latch about 1/2 the time upon opening. This must be corrected so that they self-latch every time.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(f) Vacuum lines shall have protective caps. Pools constructed after May 1, 2010, shall have a self-closing cap designed to be opened with a tool.
Observed vacuum line to be uncapped upon arrival. Cap was provided and installed. -CDI.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed all of the bathroom sinks to be non-functional. These must be corrected and function properly.
Mar 11, 2026 6 demerits · 1 violation
Inspector comments: Inspection conducted with CPO William Winston.
Emergency phone signage fading. Correct dialing instructions on Kings III phone, emergency phone sign has incorrect dialing instructions. Recommend replacing emergency phone signage with one that has correct dialing instructions in addition to the address, phone number, and other verbiage on the existing sign.
Ball valve handle for main drain line broken. Recommend replacing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short. .2530(a) Provide USCG approved ring buoy with attached 34 foot, six inch throw rope at least 1/4 inches diameter. - Corrected.
Sep 3, 2025 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO William Winston.
Depth marker at ADA lift cracked. Maintain in good condition.
Ensure windows from units adjoining the pool deck are not capable of opening > 4”.
Outer rope on ring buoy fraying. Recommend replacing with a new US Coast Guard approved ring buoy and 34 foot 6 inch throw rope at least 1/4 inch in diameter.
Emergency phone signage faded. Recommend providing new signage with correct dialing instructions, address, and phone number for the emergency phone.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights burned out in men’s and women’s restrooms. .2524(b) Lighting shall be sufficient to illuminate all parts of the pool, the water, the depth markers, signs, entrances, restrooms, safety equipment and the required deck area and walkways.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on pump room floor does not flow to the drain. .2533(d) Pump room floor shall be sloped to drain.
Standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water.
May 15, 2025 22 demerits · 5 violations
Inspector comments: Inspection conducted with manager Trey Watson.
Depth marker at ADA lift cracked. Maintain in good condition.
Ensure windows from units adjoining the pool deck are not capable of opening > 4”.
Outer rope on ring buoy fraying. Recommend replacing with a new US Coast Guard approved ring buoy and 34 foot 6 inch throw rope at least 1/4 inch in diameter.
Our office has not yet processed the pool permit application and payment. Current permit expires 5-31-2025.
All items marked as Intent to Suspend items must be corrected before the permit expires on 5-31-2025 or the pool permit will be suspended.
Immediate suspension issued
22)
Contact Will Harrison (704) 754-2130 for re-inspection once issues have been corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place for main drain checks on pool log sheet. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
CPO on file no longer works here. Provide updated certification for new CPO. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Leaves in skimmer baskets. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
Incorrect dialing instructions on emergency phone sign. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
Sep 9, 2024 12 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Daniel Wright.
Outer rope on ring buoy starting to fray. Recommend replacing with new U.S. Coast Guard approved ring buoy.
Pole for Body hook. Bent. Recommend replacing with new 12 foot long non-collapsible pole.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some recent records missing. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Leaves in skimmer baskets. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
Apr 8, 2024 16 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Daniel Wright.
Daniel is the new CPO for this pool. Updated CDP with CPO information.
6” depth marker cracked by ADA lift. Maintain depth markers in good condition.
Intent to suspend issued
5)
16)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place for main drain checks on pool log sheet. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One of the windows that opens to the pool deck opened all the way. Window limiter missing. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items stored next to pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Light burned out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in restrooms. .2526(l) Provide toilet paper on dispensers in restrooms.
Jul 25, 2023 20 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Nick Wilson.
Depth marker by ADA lift cracked. Recommend replacing.
*NOTE* Main drains expire 10-10-2023. Prior to drain cover expiration will need to replace with new VGBA approved covers and submit updated PDSC form to our department.
Kings III and 911 operator had difficulty hearing me. Recommend checking the phone line.
Immediate suspension issued
2)
3)
Contact Will Harrison (704-507-6824) for re-inspection when issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#3 · Water quality: pool water pH −6
PH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#18 · Premises: lifeguards present or warning signs posted −4
Warning No Lifeguard on Duty sign in less than 4 inch lettering. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Intent to suspend item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Erosion feeder not functioning. Turned all the way on but no water moving through the flow meter. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
Jun 2, 2023 0 demerits · 0 violations
Inspector comments: No violations noted, pool has fixed Kings III box and is now able to make a call out and receive a call at listed number.
EHS confirmed pump and drain covers.
No night swimming.
Permit issued.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LINDEN APARTMENTS, THE” or State ID 2060530711). Inspection type (routine vs. follow-up) is not published in the county's data.