44demerits
AXIS AT THE PARK
5200 OXFORD POND DR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530719
Latest result44 demerits
Last inspectedOct 20, 2026
Inspections on record7
On record sinceAug 25, 2023
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 25, 2023Lower is betterOct 20, 2026
Inspections & violations
Oct 20, 2026 44 demerits · 12 violations
Inspector comments: 6 - Drain covers replaced. Viewed old drain covers in the pump room. New covers 2017. PDSC form does not reflect new covers and installation dates. Require new PDSC form within 1 week or permit will be suspended. Original construction/plumbing inspection shows 8" pipe to T then reduces to 6" pipe back to the pump room. New 2017 Lawson 18x18 drain covers require 8" pipe for at least 40" before reduction. Measured 10 ft. between drains prior to reduction to 6" pipe. Meets mfg. requirements.
Intent to Suspend issued for:
.2535 - Cyanuric acid reagent expired. No main drain checks. CYA approx. 110 ppm. Replace reagent, ensure daily record keeping for main drain checks and lower CYA to 100 ppm or less.
.2538 - repair front gate to self-close, self-latch.
.2533/.2537 - repair damaged piece of coping.
.2530 - Move Warning No Lifeguard on Duty inside of barrier so visible from all entries into the pool.
.2518 - install flow meter per mfg. instructions with correct inlet/outlet lengths of straight run pipe.
Move ring buoy/rope and body hook that is blocked by landscaping so accessible within 30 days.
Michael St. John new CPO. Viewed CPO certification while onsite.
NOTES: 1 Pumps remain set at 3450 RPM or flow shall remain at 242 gpm to 396 gpm to meet turnover and flow restriction of return pipe size. 2)Fence along back of retaining wall ok at >2” due to height of retaining wall. 3) Hose bib for restrooms is located on outside wall.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid reagent expired. No main drain checks. CYA approx. 110 ppm. Replace reagent, ensure daily record keeping for main drain checks and lower CYA to 100 ppm or less. Intent to Suspend issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some algae build-up on pool walls and around ladders. Keep pool clean. Monitor and treat as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
All skimmer baskets full of debris. Emptied during the inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook/ring buoy with 50 ft rope on back side of pool not accessible due to landscaping. Move body hook/ring buoy within 30 days.
One ring buoy rope tangled. Keep accessible in case of emergencies. Corrected during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main gate into pool at parking area not latching. Repair gate to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping cracked and broken off at left side of pool near ladder. Repair coping. Intent to Suspend issued.
Multiple areas where deck is cracking, coping caulking is damaged or separating. Deck appears to be moving. Skimmer closest to clubhouse near ladder with slight offset around skimmer. Monitor. If offsets or damage are >1/2", repair will be required.
#18 · Premises: lifeguards present or warning signs posted −4
Warning signage located outside of the main pool gate. Re-locate signage so visible upon entry to pool from all entrances. Intent to Suspend issued.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chlorine/acid line into return line leaking. Leak did not warrant repair at time of inspection. Repair leak to ensure pump room floor remains dry.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter installed does not meet 10% accuracy requirement. Not installed per mfg. instructions. Flow meter on 4" line and requires 20" of straight run pipe before the flow meter and 8" after. Digital flow meter is located within required straight run pipe. Intent to Suspend issued. Install flow meter per mfg. instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leak at feeder lines into the return line. Keep pump room floor dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Men's restroom door locked from inside. Keep accessible.
Men's restroom with no soap. Provide soap for handwashing.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Aufofill float has been removed from inside of the autofill and not working. Repair autofill so functional.
Apr 24, 2026 10 demerits · 2 violations
Inspector comments: Inoperable flow meter. Please repair with 7 days. Call James Bjorneboe at 704-507-6820 to schedule reinspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed both throw ropes longer than 50 feet. Corrected onsite.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed digital flow meter inoperable. Repair.
.2518(g) Keep flow meter operational.
Oct 1, 2025 16 demerits · 4 violations
Inspector comments: Issued immediate suspension for #2 (chlorine). Pool is to remain closed until chlorine is brought to acceptable levels. Please call James Bjorneboe @ 704-507-6820 once items have been corrected.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at a minimum of 1.0 ppm.
.2535(4) Maintain chlorine at least 1.0 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing on one ladder. Replace.
.2521 Install ladders per manufacturer instructions.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Unable to determine return flow due to inoperable flow meter. Repair/replace flow meter.
.2518(g) Keep flow meter operational.
Jan 23, 2025 0 demerits · 0 violations
Inspector comments: Observed all gates self-closing/ self-latching. Body hooks were connected to poles. No other violations were observed during inspection.
No violations were recorded for this inspection.
Oct 29, 2024 22 demerits · 5 violations
Inspector comments: Issued immediate suspension for pH and body hook/pole issues. Pool is to remain closed until items have been corrected. Once corrected, call James Bjorneboe st 704-507-6820 to schedule re-visit.
General Comment: Unable to access pump room and chemical room at time of inspection. Further permit action might be required at time of revisit if pump room and chemical rooms remain inaccessible.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain pH between 7.2 and 7.8.
.2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in pool skimmers. Keep pool skimmers free of excessive debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing end cap on one ladder. Replace.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed one body hook not attached to pole. Observed other body hook attached to a retractable/ telescoping pole. Hooks must be attached to a single piece pole at least 12 feet in length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate closest to clubhouse not self- latching. Ensure all gates are kept self-closing/ self-latching.
.2537(b) All gates and doors shall be self-closing, self-latching.
Feb 7, 2024 12 demerits · 3 violations
Inspector comments: Konya Parker lead the inspection.
Issued immediate suspension for #3 ( ph levels)
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed ph at 8.0. Maintain ph between 7.2 to 7.8
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer. Keep skimmers free of debris
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor. Repair leak. Observed unable to access chemical room due to boxes and barrels blocking entrance. Please clear area to maintain access.
Aug 25, 2023 0 demerits · 0 violations
Inspector comments: Permit approved.
Observed no non-compliant conditions.
Permit Restriction:
1) Pumps must remain set at 3450 RPM or flow meter shall remain operable at 242 gpm to 396 gpm to meet turnover and flow restriction of return pipe size.
2) Fence along back of retaining wall ok at >2” due to height of retaining wall.
No violations were recorded for this inspection.