RESERVE AT STONE HOLLOW

8800 HOLLOW CREEK CIR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530720
Latest result14 demerits
Last inspectedJun 17, 2026
Inspections on record10
On record sinceAug 7, 2023

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02856 Aug 7, 2023: 4Mar 13, 2024: 56Aug 12, 2024: 36Aug 15, 2024: 26Mar 12, 2025: 30Jun 26, 2025: 34Jul 2, 2025: 24Jul 3, 2025: 14Apr 30, 2026: 36Jun 17, 2026: 14
Aug 7, 2023Lower is betterJun 17, 2026

Inspections & violations

Jun 17, 2026 14 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Mohammad Safi. New pump motor installed. Electrical permit COM-ELC-26-005488 passed 6/15/2026. New TR 140C filter installed. Verified in-field plan review items. Verified flow at 110 GPM after a backwash at 3200 RPM. New permit condition that flow meter must remain operable and be between 98 and 120 gpm for minimum turnover and flow restriction of the number of returns. WARNING NO LIFEGUARD ON DUTY sign some wording is less than 4”. Will need to provide extra signage in at least 4” lettering. Some cracked depth markers, missing grout around no diving marker. Maintain in good condition. Kings III phone cuts in and out. Maintain in good condition. Recommend having Kings III check the emergency phone. Permit issued with the following conditions: No night swimming Flow meter must remain operable. Flow required at 98 to 120 GPM to meet turnover and flow restriction of the number of returns. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 1-3 business days for your records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Plugs missing in skimmer equalizer lines. .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. - Will follow up with facility to ensure corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water comes out of the pump room floor drain when backwashing. .2533(d) Pump room floor shall be kept dry and free of standing water. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some bags of chemicals on the ground in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One light burned out, other light flickering in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Apr 30, 2026 36 demerits · 9 violations
Inspector comments: Inspection conducted with CPO Armando Benitez. New Triton II Filter installed. Will need to fill out an in-field plan review application for newly installed equipment before 2026 pool permit will be issued. Application is on our website https://eh.mecknc.gov/pools. New motor installed on pump. Prior to 2026 permit being issued, will need an electrical permit and passing inspection from Mecklenburg County Code Enforcement. Main drain mostly closed and all but one skimmer return tabbed closed. Maintain equipment to allow for proper water circulation. Permit condition that flow required at 106 GPM to 146 GPM to meet turnover and flow restriction of the filter. Blue-White flow meter not installed per manufacturers instructions. Prior to 2026 permit being issued will need to install a flow meter that is accurate to within +/- 10%. Intent to suspend issued 5) 16)
#3 · Water quality: pool water pH −6
PH > 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.5.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spotty records. No main drain, cyanuric acid or total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
All the skimmers except one tabbed closed. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short, tied to all of the beckets. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope at least 1/4 inch in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate by pump room with latch < 54”. .2528(a) Gate latches shall be 54" in height. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Jul 3, 2025 14 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Clay Massenburg and maintenance supervisor Natural Scott. Verified items from previous inspection on 6/26 and 7/2. Conducted pre-permit inspection. Issues corrected Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records. Permit sticker issued with the following conditions: No night swimming.
#3 · Water quality: pool water pH −6
PH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.7.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
One depth marker on pool wall by ladder with incorrect depth. Should be 3ft, says 3ft 6 in. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate by pump room with latch < 54”. .2528(a) Gate latches shall be 54" in height. - Corrected.

View this inspection on the county portal ›

Jul 2, 2025 24 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Clay Massenburg. Verified items from previous inspection on 6/26/2025 and conducted pre-permit inspection. Depth markers on pool walls and pool deck do not match. Measured by each of the depth markers to verify which were correct on last inspection. All depth markers on pool deck are now correct. Will need to make the depth markers on pool walls match what is on the pool deck. Inspection did not pass. Immediate suspension still in place. 3) 7) 9) 16) 23) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980) 314-1620 and paying with a credit card.
#2 · Water quality: disinfectant residual provided by −6
0.2ppm of free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Pre-permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth markers on pool wall and pool deck do not match. Some give inaccurate depths. See note at end of inspection. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Pre-permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Less than 45” from ground to top horizontal on some gates. .2528(a) Maintain 45" between bottom horizontal and next horizontal on gates. - Pre-permit item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Automatic feeder running, but not able to feed liquid chlorine into the pool. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Pre-permit item.

View this inspection on the county portal ›

Jun 26, 2025 34 demerits · 9 violations
Inspector comments: Inspection conducted with CPO Clay Massenburg. Discussed ladder and depth markers with contractor Manuel Samy with Manuel Samy Pools. Depth markers on pool walls and pool deck do not match. Measured by each of the depth markers to verify which were correct. 3FT 6IN depth marker by ladder on pool deck will need to be changed to 3FT. All other depth markers on pool deck are correct. Will need to make depth markers on pool walls match what is on the deck. Recommend adding another 5FT depth marker by underwater light near main drain on pool wall and one on pool deck so it is no longer > 25 FT between depth markers. Ensure depth tile on pool deck is non-slip. Pre-permit inspection did not pass: 6) 7) 9) 11) 16) 22) 24) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980) 314-1620 and paying with a credit card.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Suction hazard. Vacuum cap not latching, vacuum on in the pump room. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves on pool surface. Did not move to skimmers during inspection. Ensure skimmers are working and eyeball fittings are arranged to provide uniform water circulation. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
More than 25 feet between depth markers on pool wall and pool deck by main drains. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Pre-permit item. Depth markers on pool wall and pool deck do not match. Some give inaccurate depths. See note at end of inspection. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Pre-permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder anchors recently changed. One ladder good, other ladder extend ~8 inches into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate by pump room does not latch. All three gates open in towards the pool. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item. Less than 45” from ground to top horizontal on some gates. .2528(a) Maintain 45" between bottom horizontal and next horizontal on gates. - Pre-permit item. Gap greater than 2” under some gates. .2528(a) Maintain 2" or less under gates. - Pre-permit item.
#22 · Premises: emergency telephone provided −6
Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in men’s restroom. No toilet paper in both stalls in the women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms. No soap in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Mar 12, 2025 30 demerits · 9 violations
Inspector comments: Inspection conducted. Went over inspection with Manager Erica Romero. Permit condition - Pool gates with < 45” between horizontals. Prior to 2025 permit being issued. Will need to eliminate footholds by installing metal mesh, plexiglas, or equivalent on the outside of the gates or replacing with new gates that meet requirements in .2528. Observed pump turned down to 2800 RPM. Very little flow in skimmers, debris on water surface. Ensure pump speed is set high enough to maintain proper water turnover. Not able to test automatic chlorinator. Ensure automatic chlorinator shuts off when the pump shuts off. Observed broken glass by door to pump room. Ensure glass is cleaned up, maintain pool area free of glass. Intent to suspend issued 5) 7) 8) 9) 16) 17)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records since January. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris on pool floor and water surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. Some wall tiles cracked, broken, or missing. .2537(14) Maintain pool walls in good condition.- Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth marker broken, tile loose. .2523(c) Depth markers shall be slip resistant and maintained in good condition. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Main gate does not latch. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. Concrete decking around ladder in deep end cracked and chipping. .2537(2) Decks shall be kept in good repair. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chlorine line on automatic feeder leaking. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan in pump room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Aug 15, 2024 26 demerits · 8 violations
Inspector comments: Inspection conducted with CPO Clay Massenburg and the property manager. Conducted pre-permit inspection. Verified items from previous inspection as well. Pool gates with < 45” between horizontals. Prior to 2025 permit being issued. Will need to eliminate footholds by installing metal mesh, plexiglas, or equivalent on the outside of the gates or replacing with new gates that meet requirements in .2528. Permit issued No Night Swimming Paper permit will be available on our website for your records in 3-5 business days.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Back gate not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room and chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in one of the stalls in the women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Aug 12, 2024 36 demerits · 10 violations
Inspector comments: Inspection conducted with CPO Clay Massenburg. Conducted pre-permit inspection. Verified items from previous inspection as well. Main drains and equalizer line covers replaced, verified PDSC information. Pool gates with < 45” between horizontals. Prior to 2025 permit being issued. Will need to eliminate footholds by installing metal mesh, plexiglas, or equivalent on the outside of the gates or replacing with new gates that meet requirements in .2528. Pre-permit inspection did not pass. 5) 9) 16) 17) 22) Inspection scheduled for 11:00 AM on 8/15. Prior to inspection, will need to pay $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Test kits expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Pre-permit item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
27 feet between depth markers on pool wall by main drains. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Pre-permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New US Coast Guard approved ring buoy with 30 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope at least 1/4 inch in diameter. - Corrected. Operator able to use old throw rope.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Weld on back gate broken. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Pre-permit item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Trash can too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item.
#22 · Premises: emergency telephone provided −6
Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room and chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in one of the stalls in the women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Mar 13, 2024 56 demerits · 14 violations
Inspector comments: Inspection conducted with maintenance supervisor Darren Nowlin. Some deck tiles cracked. Maintain in good condition. Observed 2 weeks in January and February pH was consistently 8.0 with no corrective actions taken. Ensure that pool is being properly maintained and chemical adjustments are made as needed. Note any maintenance activities and pool chemical additions in pool log sheet. Main drains expire April 10, 2024, equalizer line covers expire April 30, 2024. Replace with ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to MeckPools@MeckNC.gov for approval. Immediate suspension issued 3) 6) 15) 22) Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.
#3 · Water quality: pool water pH −6
PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Test kits expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main drain damaged. Some fins broken off. .2537(7) Drain covers shall be in good condition and securely attached. - Immediate suspension item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Missing a few wall tiles. .2537(14) Maintain pool walls in good condition. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two weirs missing, one weir sticks. .2518(k) Provide functional weirs. - Intent to suspend item. Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
27 feet between depth markers on pool wall by main drains. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder missing slip-resistant tread. .2521(b) Ladders shall have slip-resistant tread. Both ladders missing endcaps. Both ladders with loose steps. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy damaged. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room and chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Dry chemical stored on the floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Lock to pump/chemical storage room removed, not capable of locking. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. No light in the pump room. .2533(b) Provide sufficient lighting in pump room. Light burned out in the chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in one of the stalls in the women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Aug 7, 2023 4 demerits · 1 violation
Inspector comments: FACILITY CHANGED TO ANNUAL PERMIT AFTER INSPECTION OCURRED. SEE 501196. FROM SHELTON INSPECTION: Buoy rope meets 45’ length requirement. Operator had to take out several knots to meet length requirement.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “RESERVE AT STONE HOLLOW” or State ID 2060530720). Inspection type (routine vs. follow-up) is not published in the county's data.