24demerits
SOLIS MIDTOWN APARTMENTS
1133 HARDING PL, Charlotte, NC 20204
Year-Round Swimming Pool · NC permit/State ID 2060530725
Latest result24 demerits
Last inspectedSep 21, 2026
Inspections on record7
On record sinceDec 4, 2023
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Dec 4, 2023Lower is betterSep 21, 2026
Inspections & violations
Sep 21, 2026 24 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Alex Morales. Alex is the new CPO for this pool, provide copy of CPO certification.
Property now managed by RPM Living. Emailed copy of application to the manager to update and email back.
Permit condition that feature pump flow meter must remain operable. Flow required at 62 gpm or less due to suction pipe flow restriction. Verified at 48 GPM today.
Permit condition that Filtration pump flow meter must remain operable. Flow required at 83 gpm to 120 gpm to meet turnover and return # restriction. Verified at 118 GPM today.
Outer rope on ring buoy frying. Recommend replacing with new US Coast Guard approved ring buoy with attached 50 foot throw rope at least 1/4 inches in diameter.
Kings III had difficulty hearing me, static on the line. Recommend having Kings III check the emergency phone.
Immediate suspension issued
3)
Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
New CPO. Provide CPO certificate to our office. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Most of the fence < 48” high. Ensure no gaps > 2” under the fence after removing mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chlorine feeder not functioning. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Jan 9, 2026 22 demerits · 5 violations
Inspector comments: Call Chris Sells when pool chemistry is correct at 704 576 8678.
Recommend not storing chemicals in pump room.
Observed feature drains Aquastar A10RCFRxxx with riser rings backwards.
Correct or disable feature pump prior to requesting a return inspection.
Immediate suspension for:
.2535(1) Maintain pH at 7.2 to 7.8.
#3 · Water quality: pool water pH −6
Observed pH at 7.0
Immediate suspension. Raised to 7.1 during inspection
.2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Repeat: Observed no records of cyanuric acid for the last 9 days
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate near pump house not self-latching. Latch mechanism not properly functioning.
Corrected during inspection.
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning during inspection. Kings III issues on Kings III side, corrected during inspection.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed exhaust fan not functioning.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Dec 4, 2025 24 demerits · 5 violations
Inspector comments: Emergency phone callback should be able to audibly call back to phone and connect in case of emergency when number posted at phone is dialed after call out. Contact Marie Daley at 704-507-6806 when corrected. Will make visit by 12/11/25 to verify operation of emergency phone.
Unable to check windows onto pool deck. These should not open greater than 4”.
Inspection with Jun Nawa
No Night Swimming
Permit Restrictions:
1) Pool is not approved for salt as primary chlorination.
2) Filtration pump flow meter must remain operable. Flow required at 83 gpm to 120 gpm to meet turnover and return # restriction.
3) Feature pump flow meter must remain operable. Flow required at 62 gpm or less due to suction pipe flow restriction.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly cyanuric acid checks.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Filtration pump flow meter reading over 130 gpm. Permit restriction is required flow 83-120 gpm. Operator adjusted speed of pump and lowered to 120 gpm. Corrected.
Feature pump off at time of inspection. Permit restriction for feature is maintaining less than 62 gpm due to suction hazard. Ensure flow rating does not exceed 62 gpm when operating. Unable to verify at time of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy blocked by chairs and pool furniture. .2530(a) Lifesaving equipment should be conveniently located. Operator moved furniture to make accessible. Corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone having callback difficulties at time of inspection. Phone audible rang after hanging up with no entity on other line, started 3 way call to emergency at callback of number, then remained busy signal at call back. Not fully operational for callback. Since phone is dialing out to 911, allowing 7 days, 12/11 for correction of callback and phone to be fully operational in case of emergency. Contact Marie Daley at 704-507-6806 when corrected. Permit action will be taken if phone is not fully operational at return visit.
*Permit item
.2530(f) Emergency phone shall remain operable.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3’ of equipment in pump room. Dry chemicals stored in pump room on pallet, no room in chemical storage. Chemical storage room door opened into pump room. Operator moved hoses and items within 3’ clearance of equipment.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
May 29, 2025 4 demerits · 1 violation
Inspector comments: Type:
Permit Restrictions: 1) Pool is not approved for salt as primary chlorination. 2) Filtration pump flow meter must remain operable. Flow required at 83 gpm to 120 gpm to meet turnover and return # restriction. 3) Feature pump flow meter must remain operable. Flow required at 62 gpm or less due to suction pipe flow restriction.Filtration drains expire - 3/15/2030. Feature drains expire - 9/12/2028
All flows and PDSC information verified.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Mulch build up on exterior of fence causing some areas to be less than 48” from mulch to fence top. Maintenance began raking back build up. No permit action required at this time.
Maintain 48” in all areas.
Dec 18, 2024 4 demerits · 1 violation
Inspector comments: Immediate suspension for imminent hazard of pool lights.
Lights not secure to wall.
Call Chris Sells when repairs are completed at 704 576 8678.
Pool is not permitted to open until a follow up inspection is completed by the Department
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed lights on wall not secure. Immediate suspension.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Jan 31, 2024 0 demerits · 0 violations
Inspector comments: Observed no non compliant conditions.
No violations were recorded for this inspection.
Dec 4, 2023 0 demerits · 0 violations
Inspector comments: Observed no non compliant conditions.
Feature pump cannot exceed 62gpm.
Filtration pump must be between 83gpm and 120gpm.
Permit issued.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SOLIS MIDTOWN APARTMENTS” or State ID 2060530725). Inspection type (routine vs. follow-up) is not published in the county's data.