2demerits
CADIA MILLENNIUM
5108 ACADIA HEIGHTS DR, Charlotte, NC 28217
Year-Round Swimming Pool · NC permit/State ID 2060530733
Latest result2 demerits
Last inspectedJul 14, 2026
Inspections on record6
On record sinceMay 24, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 24, 2024Lower is betterJul 14, 2026
Inspections & violations
Jul 14, 2026 2 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Jose Rivera.
Observed flow meter for filtration pump programmed to above 80 gpm. CPO corrected during inspection and EHS observed flow meter was now reading 79 gpm. Feature pump flow meter was at correct gpm.
Permit Restrictions: 1) Filtration Pump Flow meter shall remain operable. Flow shall be maintained at 68 gpm to 80 gpm to meet turnover and flow restriction with number of returns. 2)Feature Pump Flow meter shall remain operable. Flow shall be maintained at 105 gpm to meet flow restriction of 2” return line. 3) Pool is not approved for salt as primary chlorination.
NO NIGHT SWIMMING. Construction date: 9/01/2023 Rope length: 45'
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed bags of sodium bicarbonate stored directly on the floor inside chemical storage room.
CPO removed bags off of the floor.
Feb 10, 2026 34 demerits · 8 violations
Inspector comments: Inspection conducted with new CPO Jose Rivera. Pool leaking. Property in process of repairing. Permit suspended for emergency phone and inoperable flow meter. Pool placed on E status and must close with signs posted. Other deficiencies must be addressed upon re inspection or 30 day intent to suspend will be issued. Call EHS Devon when ready for re inspection 7049981122.
Reminder: Pool application and payment due by the last business day of February.
Note: Property changing from an erosion feeder system to an electronic automatic liquid feeder system.
Feature pump flow meter: 45gpm
Feature pump not being maintained at proper GPM. Correct.
Permit Restrictions: 1) Filtration Pump Flow meter shall remain operable. Flow shall be maintained at 68 gpm to 80 gpm to meet turnover and flow restriction with number of returns. 2)Feature Pump Flow meter shall remain operable. Flow shall be maintained at 105 gpm to meet flow restriction of 2” return line. 3) Pool is not approved for salt as primary chlorination.
Const. Date: 9/1/2023 Rope Length: 45' Night Swim?: No
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Daily drain cover checks and weekly CYA and TA missing from records. Digital records. Ensure EHS has ability to review digital records.
Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Leaves present on pool floor.
Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
.2518(k) Water level shall be maintained to assure skimmers are operable.
Simmers full of leaves and water level too low due to leak.
Intent to suspend items.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
Several gaps under fence over 2”
Intent to suspend item.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
Main pool sign broken and not posted. Replace.
Intent to suspend item.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area.
Main pool rules sign broken and not posted.
Intent to suspend item.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Emergency phone not operational.
Provide sign with accurate dialing instructions. Current signs instructs to push button. Actual unit is a handset with no button.
Immediate suspension items.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Feature pump flow meter not operational.
Immediate suspension due to flow restriction
Sep 2, 2025 8 demerits · 2 violations
Inspector comments: Conducted inspection with CPO Brandon. Pool remains in good standing and on A status.
Windows on
pool deck have limiters.
No night swimming.
Feature flow meter 45gpm.
Permit Restrictions: 1)
Filtration Pump Flow
meter shall remain
operable. Flow shall be
maintained at 68 gpm to
80 gpm to meet turnover
and flow restriction with
number of returns.
2)Feature Pump Flow
meter shall remain
operable. Flow shall be
maintained at 105 gpm to
meet flow restriction of 2”
return line. 3) Pool is not
approved for salt as
primary chlorination
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope snapped. Operator replaced and cut to approved 45ft length. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Water on pump room floor. Find leak and repair.
May 22, 2025 6 demerits · 1 violation
Inspector comments: Conducted inspection with GM and CPO Brandon. Immediate suspension issued due to inoperable emergency phone. Call EHS Devon when repaired and ready to open. 7049981122. Deck pop repaired by replacing coping on right side of the pool. Windows on pool deck have limiters. Records not being maintained due to pool being closed. Ensure records are kept while pool is open.
Feature flow meter 45gpm.
Permit Restrictions: 1)
Filtration Pump Flow
meter shall remain
operable. Flow shall be
maintained at 68 gpm to
80 gpm to meet turnover
and flow restriction with
number of returns.
2)Feature Pump Flow
meter shall remain
operable. Flow shall be
maintained at 105 gpm to
meet flow restriction of 2”
return line. 3) Pool is not
approved for salt as
primary chlorination.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone not operational due to fiber cable being cut down the road. Immediate suspension item.
Aug 29, 2024 12 demerits · 3 violations
Inspector comments: Performed inspection with CPO Brandon Mickles.
Immediate suspension issued for high pH and high flow not meeting flow restriction.
Call or text EHS Devon Moeller when items have been corrected and pool is ready to open. 7049981122
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. EHS observed pH at 8.4. Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Pump not meeting requirements of flow restriction. EHS observed flow at 95gpm. Operator unable to correct in field. Flow shall be maintained at 68gpm to 80gpm to meet turnover and flow restriction with number of returns. Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Move to designated chemical storage room.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of chemicals on ground in chemical storage room. Raise off floor.
May 24, 2024 0 demerits · 0 violations
Inspector comments: Observed deck concrete repaired completed.
Pump was over 90 gpm. Required to be 68 to 80gpm. Corrected to 70gpm during inspection.
Permit issued
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CADIA MILLENNIUM” or State ID 2060530733). Inspection type (routine vs. follow-up) is not published in the county's data.