30demerits
AYRSLEY LOFTS
9336 KINGS PARADE BV, Charlotte, NC 28273
Year-Round Swimming Pool · NC permit/State ID 2060530734
Latest result30 demerits
Last inspectedAug 12, 2026
Inspections on record8
On record sinceMay 1, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 1, 2024Lower is betterAug 12, 2026
Inspections & violations
Aug 12, 2026 30 demerits · 8 violations
Inspector comments: Conducted inspection with CPO. Intent to suspend issued for missing pool records.
Permit Restriction: Filtration pump flow meter must remain operable with flow at 84 gpm to 98 gpm to meet turnover and flow restriction of the filter.
Const. Date: 7/1/2016 Rope Length: 42' Night Swim?: No
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
Chlorine observed at 0.0ppm. Operator corrected to 2ppm. No permit action.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
PH observed at less than 7.0. Operator corrected to 7.2. No permit action.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable.
No records for August. Main drain checks missing for July. Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Skimmer baskets full of leaves and under baskets full of leaves blocking flow. Operator emptied and cleaned out. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height.
Resident items pushed up against balcony fences creating footholds. Remind residents to keep patio fencing clear of furniture. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. No 3’ clearance around equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided.
Provided shower not operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restrooms.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
Feb 18, 2026 14 demerits · 4 violations
Inspector comments: Issued 30 Day Intent to Suspend (ITS) for doors. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
Filtration must remain between 84-98 gpm. May require new flow meter in future for flow reduction.
No night swimming. Pool not heated.
Inspection with Tripp Arcury
“W” ITS status
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Table and coolers against resident fencing in 2 locations creating horizontal less than 45”. Door onto pool deck from resident hallway not latching at time of inspection.
.2537(b) All doors shall be self-closing, self-latching or audible alarm.
.2528(b) Horizontals shall not be located less than 45" in height.
Items moved back from fencing to eliminate horizontals. Corrected.
*Door is permit item
#22 · Premises: emergency telephone provided −6
Not able to hear emergency operator at call out.
.2530(f) Emergency phone shall remain operable. Adjusted volume and corrected. Monitor to ensure phone works at all times in case of emergency.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. No 3’ clearance around equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restrooms. No paper towels in men’s restroom. Faucet not working/staying on in women’s restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Oct 15, 2025 28 demerits · 9 violations
Inspector comments: Inspection conducted with office staff.
Tile line very dirty, difficult to read wall depth markers. Clean pool wall tiles.
CPO not present. Not able to test automatic chemical feeder. Ensure automatic chemical feeder shuts off when the pump is off.
New cabanas installed by sunshelf partially block view of pool rules sign, relocate rules sign so that it is easily visible.
New feature pump motor installed. Electrical permit COM-ELC-25-003722 passed inspection 9/3/2025.
Intent to suspend issued
5)
8)
16)
17)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records for the last two weeks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two of 4 weirs stuck. .2518(k) Provide functional weirs. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Window to right of Warning-No Lifeguard on Duty sign open > 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item.
Back gate sticks, doesn’t always self-latch. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck cracked with loose pieces of concrete. .2537(2) Decks shall be kept in good repair. - Intent to suspend item.
Coping loose at sunshelf. .2537(3) There shall be no loose coping. - Intent to suspend item.
#18 · Premises: lifeguards present or warning signs posted −4
Primary rules sign partially obscured by new cabana’s. Not easily visible. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some pool piping not labeled or labels wearing off. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
Toilet in men’s restroom running. 2526(m) Keep restrooms and fixtures clean and in good repair.
Jun 2, 2025 12 demerits · 4 violations
Inspector comments: Lifted suspension. Issued permit. No Night Swimming. Pool not heated.
Permit Restriction: Filtration pump flow meter must remain operable with flow at 84 gpm to 98 gpm to meet turnover and flow restriction of the filter.
Verified following and found noted differences:
New Pump Hayward HCP2500VSP, 2.7 THP
Blue white flow meter installed on 2” line reading 85 gpm. (This was original suspension item from expired ITS, corrected), label piping.
Main Drain and Skimmer 4” line; Return 3” line at floor with 2” tie in. Main drain and skimmer coming out of ground are 4” and all change to 2” piping for filtration and skimmer.
(2) Aquastar R12MFxxx 2017 drain covers (4 total drains)
Pentair TR100C filter.
6 wall returns (autofill also has a return fitting on it). This is actually 5 wall returns, 1 floor return at sunshelf for 6 returns, 1 autofill with return fitting and vacuum line covered
(4) skimmers
Inspection with Tripp Arcury
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate not latching at time of inspection. Observed windows open onto pool deck more than 4”. Planter against resident fencing creating horizontal less than 45”.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
.2528(b) Horizontals shall not be located less than 45" in height.
Operator adjusted gate to self-close, self latch. Windows were shut and secured to not open more than 4”. Planter moved back from fencing to eliminate horizontal. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
No soap in women’s restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
Oct 15, 2024 12 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Felix Gonzalez.
Intent to suspend issued
24)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed 2” flow meter installed on 3” return line. Not giving an accurate reading. .2518(g) Install flow meter on return line per manufacturer instructions that is capable of reading within +/- 10% of true flow. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
Jun 5, 2024 22 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Felix Gonzalez and manager Gabrielle Duet.
Ensure all windows that open onto the pool deck are not capable of opening > 4”.
Will need to pay a $100 re-inspection prior to rescheduling inspection. Invoice for today’s and May 1st’s inspection emailed to the facility.
Pre-permit inspection did not pass
7)
16)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Facility working to get this corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New ring buoy with 56 foot throw rope. .2530(a) Provide US Coast Guard approved ring buoy with attached 42 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door to apartments does not latch. Magnetic latch not functioning. .2537(b) All gates and doors shall be self-closing, self-latching. - Pre-permit item.
Window limiters removed from windows in the clubhouse, allowing windows to be opened all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Corrected.
Gate not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
Jun 5, 2024 14 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Felix Gonzalez and manager Gabrielle Duet.
Permit issued
No Night Swimming
Paper permit will be available on our website in 3-5 business days for your records.
#2 · Water quality: disinfectant residual provided by −6
0.5ppm free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 1ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Facility is working to correct.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
May 1, 2024 24 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Felix Gonzalez.
Safety signage heavily faded. Difficult to read. Recommend replacing. Ensure new signage meets requirements.
Ensure all windows that open onto the pool deck are not capable of opening > 4”.
Pre-permit inspection did not pass
8)
15)
22)
24)
Will need to pay a $100 re-inspection fee prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing. .2518(k) Provide functional weirs.
One skimmer not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Permit item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook with one screw. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Permit item.
Outer rope on ring buoy heavily worn. .2530(a) Provide USCG approved ring buoy with attached 42 foot throw rope at least 1/4 inch in diameter. - Permit item.
#22 · Premises: emergency telephone provided −6
Emergency phone not visible from most of the pool deck. Signage directing bathers to the phone location heavily faded, not legible. .2530(f) Emergency phone shall be visible from all areas inside pool enclosure. - Permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Metal bobber heavily corroded. .2518(g) Keep flow meter operational. - Permit item.
Filter pressure gauge not functioning. .2519(k) Provide operational pressure gauge on filter. - Permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “AYRSLEY LOFTS” or State ID 2060530734). Inspection type (routine vs. follow-up) is not published in the county's data.