‹ Back to search

0demerits

ELLO HOUSE - POOL

3615 TRYCLAN DR, Charlotte, NC 28217
Year-Round Swimming Pool · NC permit/State ID 2060530738
Latest result0 demerits
Last inspectedFeb 12, 2026
Inspections on record6
On record sinceApr 17, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Apr 17, 2024: 4Jun 10, 2024: 0Sep 18, 2024: 6Apr 8, 2025: 4Oct 6, 2025: 0Feb 12, 2026: 0
Apr 17, 2024Lower is betterFeb 12, 2026

Inspections & violations

Feb 12, 2026 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO William. Pool remains on A status and in good standing. Feature pump: 40gpm Permit Restrictions: 1) Filtration Pump Flow meter must remain operable. Flow shall be maintained at 67 gpm to 100 gpm to meet turnover and flow restriction of #of returns. 2) Feature Pump Flow meter shall remain operable. Flow not to exceed 62 gpm due to suction pipe flow restriction. 3) Portable vacuum required. 4) Pool not approved for salt as primary chlorination. 5)EHS shall have access to resident rooms that open directly on to pool deck during inspection for verification. 5) Sump pump required to drain pool. Note: Starguard hydrostat cover in deep end of pool. Wall drain covers tied to feature. Approved for night swimming - 5/17/2025 Const. Date: 2/6/2029 Rope Length: 33' Night Swim?: Yes Night Swim Year: 2028

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 6, 2025 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO William Herrera. Pool remains on A status and in good standing. Bubbler 35gpm Const. Date: 2/6/2024 Rope Length: 33' Permit Restrictions: 1) Filtration Pump Flow meter must remain operable. Flow shall be maintained at 67 gpm to 100 gpm to meet turnover and flow restriction of #of returns. 2) Feature Pump Flow meter shall remain operable. Flow not to exceed 62 gpm due to suction pipe flow restriction. 3) Portable vacuum required. 4) Pool not approved for salt as primary chlorination. 5)Doors must remain self- closing self-latching around pool. All windows shall be limited at 4” that open on to pool deck. EHS shall have access during inspection for verification. 5) Sump pump required to drain pool. Note: Starguard hydrostat cover in deep end of pool. Wall drain covers tied to feature. Approved for night swimming - 5/17/2025 - renewal year 2028

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 8, 2025 4 demerits · 1 violation
Inspector comments: Conducted inspection with CPO William. Feature flow meter at 30gpm. No night swimming. Pool remains in good standing and on A status. Note: Filtration pump flow must be between 67gpm and 100gpm to maintain turnover and flow restriction for number of returns. Feature pump flow must be below 62gpm due to suction pipe flow restriction.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Filtration pump flow meter stuck. Operator corrected. No permit action.

View this inspection on the county portal ›

Sep 18, 2024 6 demerits · 1 violation
Inspector comments: Conducted inspection with CPO William Herrera. All items in compliance by end of inspection. Feature pump at 35gpm
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall be accessible to all pool users. Plants in pot blocking phone visibility. Operator removed plants and corrected. No permit action. EHS recommends moving pot as well.

View this inspection on the county portal ›

Jun 10, 2024 0 demerits · 0 violations
Inspector comments: Conducted follow up inspection with CPO William Herrera. All items in compliance. Feature pump at 38gpm.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2024 4 demerits · 2 violations
Inspector comments: OSV to pool for return construction and operating permit inspection. Construction passed. Holds released in system. Permit issued for no night swimming. Pool Permit Restrictions: 1)Filtration Pump Flow meter must remain operable. Flow shall be maintained at 67 gpm to 100 gpm to meet turnover and flow restriction of #of returns. 2)Feature Pump Flow meter shall remain operable. Flow not to exceed 62 gpm due to suction pipe flow restriction. 3)Portable vacuum required. 4)Pool not approved for salt as primary chlorination. 5)Doors must remain self-closing, self-latching around pool. All windows shall be limited at 4” that open on to pool deck. EHS shall have access during inspection for verification. 6) Sump pump is required. Note: Starguard hydrostat cover in deep end of pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One bag of bicarb on chemical storage room floor. Keep storage up off the floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One toilet without toilet paper in men's restrooms. Corrected during inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ELLO HOUSE - POOL” or State ID 2060530738). Inspection type (routine vs. follow-up) is not published in the county's data.