‹ Back to search

10demerits

PROSE MCCULLOUGH STATION

8424 N TRYON ST, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530744
Latest result10 demerits
Last inspectedFeb 18, 2026
Inspections on record5
On record sinceMay 3, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 May 3, 2024: 0Oct 24, 2024: 10Feb 25, 2025: 20Oct 23, 2025: 16Feb 18, 2026: 10
May 3, 2024Lower is betterFeb 18, 2026

Inspections & violations

Feb 18, 2026 10 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no weekly records for total alkalinity or cyanuric acid for February. Maintain as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable at time of visit. Corrected onsite. .2530(f) Emergency phone shall remain operable.

View this inspection on the county portal ›

Oct 23, 2025 16 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat. Observed debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Body hook observed attached to a telescoping pole. Body hook attached to a non-telescoping pole during inspection. CDI .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy tangled. Untangled during inspection. CDI
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Signage was incorrect for the pool telephone number. Correct pool telephone number posted during inspection. CDI

View this inspection on the county portal ›

Feb 25, 2025 20 demerits · 4 violations
Inspector comments: Issued immediate suspension for inadequate chlorine levels and inoperable emergency phone. Pool is to remain closed until items are repaired. Call James Bjorneboe at 704-507-6820 once items are corrected to schedule re-visit.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at a minimum of 1.0ppm. .2535(4) Maintain chlorine at least 1.0 ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves and debris on pool floor. Keep pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#22 · Premises: emergency telephone provided −6
Unable to connect to 911 via emergency phone. Repair. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.

View this inspection on the county portal ›

Oct 24, 2024 10 demerits · 2 violations
Inspector comments: Issued intent to suspend for gate not self-closing/ self-latching. Requires repair within 30 days. Please call James Bjorneboe at or 704-507-6820 once repairs have been made. General Comment: Volume on emergency phone was very low. Look into potential issue with phone volume.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook not attached to pole. Hook must remain attached to pole at all times. Corrected onsite.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 1 gate not self-closing/ self- latching. Repair. .2537(b) All gates and doors shall be self-closing, self-latching.

View this inspection on the county portal ›

May 3, 2024 0 demerits · 0 violations
Inspector comments: Observed no non-compliant condition. Permit Restriction: 1) Flow meter must remain operable. Flow shall be maintained at 106 gpm to 138 gpm to meet turnover and flow restriction of suction pipe sizing. 2) No restriction on feature pump.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PROSE MCCULLOUGH STATION” or State ID 2060530744). Inspection type (routine vs. follow-up) is not published in the county's data.