WREN NORTHLAKE PHASE II

20011 PRESTWOOD CLUB CT, Charlote, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530746
Latest result14 demerits
Last inspectedMar 24, 2026
Inspections on record5
On record sinceApr 22, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Apr 22, 2024: 8Nov 26, 2024: 12Feb 25, 2025: 0Sep 16, 2025: 18Mar 24, 2026: 14
Apr 22, 2024Lower is betterMar 24, 2026

Inspections & violations

Mar 24, 2026 14 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Juan Merced. Issue with Kings III phone not being able to transfer call to 911. Came back from 2:05 - 2:35 PM to verify phone was corrected. Pump shall be set at 98 gpm to 141 gpm to meet turnover and flow restriction of the filter. Verified at 105 GPM today. Outer rope on ring bouy starting to fray. Recommend replacing with new US Coast guard approved ring buoy with 50 foot throw rope at least 1/4 inches in diameter. Intent to suspend issued 16)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one of five weirs. .2518(k) Provide functional weirs. Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps > 2” under the fence in a few places. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item. Gaps > 1/2” between gate and post on two of the gates. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Kings III phone not able to transfer the call to local 911. .2530(f) Emergency phone shall remain operable. - Corrected. Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.

View this inspection on the county portal ›

Sep 16, 2025 18 demerits · 4 violations
Inspector comments: Inspection conducted with Ice Matthew’s. Permit condition that filtration pump flow meter must read between 98 GPM and 141 GPM. Observed 91 GPM today, increased to 93 GPM after a backwash. Recommend having a professional check the filtration system. Flow has been decreasing on every inspection since the pool was built. Pump set on 3400 RPM.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one of five weirs. .2518(k) Provide functional weirs.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope snapped. .2530(a) Provide US Coast Guard approved ring buoy with attached 50 foot throw rope at least 1/4 inches in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some sections of fencing < 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck furniture under gazebo beside the pool. Permit condition that there be no furniture under gazebo to allow clear walkway and because view under gazebo is obstructed by pillars. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Some lounge chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.

View this inspection on the county portal ›

Feb 25, 2025 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Nathan Fox. Permit condition that filtration pump flow meter must read between 98 GPM and 141 GPM. Observed 95 GPM today, within the error range of this flow meter. No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 26, 2024 12 demerits · 3 violations
Inspector comments: Inspection conducted with inspector Patrick Mitchell and maintenance staff Juan Merced. Inspection led by Patrick Mitchell. 17) Observed water puddle by pool in a low spot on pool deck. Maintain pool deck sloped way from the pool towards a drain with no standing water. Will require remediation if deck worsens or mold/algae grows. Ensure windows that open onto the pool deck are not cable of opening > 4”. Observed exposed and unprotected wiring for ground lights. Ensure all electrical connections are installed per code and all work is done by a licensed electrician. Intent to suspend issued 16) 17)
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Sections of fencing < 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item. Most of the patio gates locked, not able to test that gates work properly. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck furniture under gazebo beside the pool. Permit condition that there be no furniture under gazebo to allow clear walkway. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. Some lounge chairs too close to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#18 · Premises: lifeguards present or warning signs posted −4
One of the safety signs mostly covered by pool net. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Corrected.

View this inspection on the county portal ›

Apr 22, 2024 8 demerits · 2 violations
Inspector comments: Permit restrictions 1)No furniture behind columns of pavilion to ensure no areas of pool are blocked. 2)Signage must remain in place at entry to club building. Signage shall state "Now entering pool deck. No glass permitted." Barrier extends to include the club area due to roll-up window. 3)Filtration pump flow meter shall remain operable. Pump shall be set at 98 gpm to 141 gpm to meet turnover and flow restriction of the filter. No flow restriction on feature pump. Permit approved. Pool is not approved for night swimming. Contact Chris Sells for questions concerning night swimming at 704 576 8678 No signature at time of inspection. Technical difficulties with CDP. Nathan Fox present during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 2 gates to balconies getting hung up on ground. Corrected during inspection. .2537(b) All gates and doors shall be self-closing, self-latching.
#18 · Premises: lifeguards present or warning signs posted −4
Observed no "warning no lifeguard on duty" sign observable upon entry to the pool deck from the clubhouse area. Corrected during inspection. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WREN NORTHLAKE PHASE II” or State ID 2060530746). Inspection type (routine vs. follow-up) is not published in the county's data.