‹ Back to search

4demerits

LINK APARTMENTS NODA 36TH I

3500 PHILEMON AV, Charlotte, NC 28205
Year-Round Swimming Pool · NC permit/State ID 2060530748
Latest result4 demerits
Last inspectedSep 30, 2026
Inspections on record6
On record sinceApr 25, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Apr 25, 2024: 0Aug 21, 2024: 8Mar 31, 2025: 0Oct 23, 2025: 0Apr 1, 2026: 0Sep 30, 2026: 4
Apr 25, 2024Lower is betterSep 30, 2026

Inspections & violations

Sep 30, 2026 4 demerits · 1 violation
Inspector comments: Inspection completed with James Allen present. Permit conditions - flow meter must remain operable. Pump shall remain set at 3450 RPM or with flow at 76GPM to 138 GPM to meet turnover and flow restriction of suction pipe size. Intent to suspend permit issued for ‘residential use only’ flow meter installed. Correct within 30 days or permit may be suspended.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) The flow meter installed shall be accurate to 10% to ensure permit restrictions are met. Observed ‘residential only’ flow meter installed. Intent to suspend issued. Correct within 30 days.

View this inspection on the county portal ›

Apr 1, 2026 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. POOL NOT APPROVED FOR NIGHT SWIMMING. PEMIT RESTRICTION 1) Flow meter must remain operable. Pump shall remain set at 3450 rpm or with flow at 76 GPM to 138 GPM to meet turnover and flow restrictions of suction pipe size. 2) Pool is not approved for salt as primary. MAIN DRAIN COVERS EXPIRE 10/28/30

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 23, 2025 0 demerits · 0 violations
Inspector comments: Observed the emergency phone to not work with phones that were not AT&T service phones. The call back function of the emergency phone should be able to work with multiple phones and services, contact the service provider and have the call back function corrected. Contact C. Elmore when the correction is made (704-507-6814). C. Elmore will follow-up on the correction on or around November 7th. The call-out function, addressing, and phone number was verified. Ensure that the windows that open onto the pool deck are limited to only open 4 inches or less. PEMIT RESTRICTION 1) Flow meter must remain operable. Pump shall remain set at 3450 rpm or with flow at 76 GPM to 138 GPM to meet turnover and flow restrictions of suction pipe size. 2) Pool is not approved for salt as primary. MAIN DRAIN COVERS EXPIRE 10/28/30

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 31, 2025 0 demerits · 0 violations
Inspector comments: 10-28-30 is the expiration date for the main drain covers. NO VIOATIONS NOTED

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 21, 2024 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed some cyanuric acid readings missed. Ensure that all daily and weekly readings are kept on the proper schedule. No Permit Action taken.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir missing. Weir was replace during inspection.

View this inspection on the county portal ›

Apr 25, 2024 0 demerits · 0 violations
Inspector comments: Observed non compliant conditions Permit issued

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LINK APARTMENTS NODA 36TH I” or State ID 2060530748). Inspection type (routine vs. follow-up) is not published in the county's data.