‹ Back to search

0demerits

ZORA UNIVERSITY AMENITY CENTER POOL

1720 ROCKY RIVER RD, Charlotte, NC 28213
Year-Round Swimming Pool · NC permit/State ID 2060530756
Latest result0 demerits
Last inspectedJun 18, 2026
Inspections on record5
On record sinceJul 19, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Jul 19, 2024: 0Sep 12, 2024: 20Apr 23, 2025: 0Oct 10, 2025: 28Jun 18, 2026: 0
Jul 19, 2024Lower is betterJun 18, 2026

Inspections & violations

Jun 18, 2026 0 demerits · 0 violations
Inspector comments: POOL HAS PASSED INSPECTION. ENSURE THAT THE CHEMICALS ARE PROPERLY STORED IN THE STORAGE ROOM. FEATURE PUMP WAS OBSERVED TO BE AT 40 GPM. POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE. Permit Restrictions: 1) Filtration Pump Flow meter must remain operable. Flow shall be kept at 54 gpm to 104 gpm to meet turnover and flow restriction of thereturn line pipe. Flow greater than 150 gpm exceeds main drains. Suction Hazard. 2) Feature Pump Flow meter must remain operable. Flow shall be kept at 90 gpm or less due to the suction pipe flow restriction. Flow greater than 150 gpm exceeds the main drains. Suction Hazard. NOTES: 1) Salt IS approved as primary chlorination. 2) Portable vacuum may be used.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 10, 2025 28 demerits · 6 violations
Inspector comments: Issued immediate suspension for chl and pH level. Pool shall remained closed until these items are corrected. Please contact inspector when the items are brought into compliance. Inspection performed by Kurtis Nelson REHS.
#2 · Water quality: disinfectant residual provided by −6
Repeat. Observed no chlorine in pool. Chlorine must be at least 1.0ppm. .2535(4) Maintain chlorine at least 1.0 ppm.
#3 · Water quality: pool water pH −6
PH observed at 8.2 .2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Repeat. Observed no daily written records for September and only first week in August. Maintain daily written records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Repeat. Side gate is not self closing/ self latching. Repair. Shown to Manager during inspection. .2537(b) All gates and doors shall be self-closing, self-latching. One slat not secured to fencing. Repair. Shown to manager during inspection. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Table, chairs, and corn hole boards. Within 6ft of pool. Both moved by manager during the inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare basket for pump could be provided. .2518(e) Provide a spare basket for pump.

View this inspection on the county portal ›

Apr 23, 2025 0 demerits · 0 violations
Inspector comments: No violations observed during inspection. General comment: Ensure recording are kept on a daily basis for maintenance drain safety/integrity. Ensure weekly records are being kept on a weekly while basis.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Sep 12, 2024 20 demerits · 5 violations
Inspector comments: Issued immediate suspension for chlorine at 0.0 ppm. Pool must remain closed until chlorine level is at least at 1.0 ppm. Please call James Bjorneboe at 704-507-6820 when ready for reinspection.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Chlorine must be at least 1.0ppm. .2535(4) Maintain chlorine at least 1.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records for September. Maintain daily written records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Both out sides gates were not self closing/ self latching. Repair. .2537(b) All gates and doors shall be self-closing, self-latching.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash is not discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Jul 19, 2024 0 demerits · 0 violations
Inspector comments: OSV to pool to verify completion of items on previous punch list. All items corrected except for openings within 18" of push bar. Facility added plexi to bottom at 18" from push bar and provided pictures. Construction passed. Holds released in system. Permit Restrictions: 1) Filtration Pump Flow meter must remain operable. Flow shall be kept at 54 gpm to 104 gpm to meet turnover and flow restriction of the return line pipe. 2) Feature Pump Flow meter must remain operable. Flow shall be kept at 90 gpm or less due to the suction pipe flow restriction. 3) Salt is approved as primary chlorination. 4) Portable vacuum required. Note - Autofill not operational. Ownership accepted autofill as is, to be repaired at future date. Email in file. Note - 3 1/2 ft depth marker on left side of pool with some paint on marker. Ensure 4" depth marker for next inspection. Ensure log books show main drain checks. Log book provided did not have section for main drain checks. Added in during the site visit. Cyanuric acid not on log book. Facility not using - on liquid. Pool Width - 25 ft.; Rope Length - 37.5 ft.; Max Depth - 3 ½ ft. Filtration Pump Pentair IntelliPro3 VSF, 013075, 3 hp pump with (2) Aquastar 32CDFLxxx VGBA-2017 drain covers. EQ lines plugged per State recommendations. Feature Pump Pentair IntelliPro3 VSF, 013065, 1.5 hp pump with (2) Aquastar 32CDFLxxx VGBA-2017 drain covers.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ZORA UNIVERSITY AMENITY CENTER POOL” or State ID 2060530756). Inspection type (routine vs. follow-up) is not published in the county's data.