6demerits
JUNCTION 49 - POOL
7521 TWITTER LN, Charlotte, NC 28213
Year-Round Swimming Pool · NC permit/State ID 2060530767
Latest result6 demerits
Last inspectedJan 13, 2026
Inspections on record5
On record sinceOct 25, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Oct 25, 2024Lower is betterJan 13, 2026
Inspections & violations
Jan 13, 2026 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in some skimmers. Ensure that skimmers are kept free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bag on sodium bicarbonate on chemical storage room floor. Corrected on site.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Jul 29, 2025 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed leaky chlorinator in pump room causing water to stand on pump room floor. Repair.
.2533(d) Pump room floor shall be kept dry and free of standing water.
Feb 27, 2025 6 demerits · 1 violation
Inspector comments: All immediate suspension items from previous inspection (pH, chlorine, and doors to deck) have been corrected.
#22 · Premises: emergency telephone provided −6
No phone number posted at emergency phone. Corrected on site.
Dec 4, 2024 24 demerits · 5 violations
Inspector comments: Issued immediate suspension for out of compliance chlorine and pH levels. Pool is to remain closed until items are corrected. Please call James Bjorneboe at 704-507-6820 to schedule revisit.
General comment: Consider using emergency phone that can transmit both address and phone number to 911.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at a minimum of 1.0ppm
.2535(4) Maintain chlorine at least 1.0 ppm.
#3 · Water quality: pool water pH −6
Observed pH at 8.4. Maintain between 7.2 and 7.8.
.2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily/weekly records onsite. Keep and maintain daily/weekly written records as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed two sets of doors not self closing/ self latching.
.2537(b) All gates and doors shall be self-closing, self-latching.
Oct 25, 2024 12 demerits · 3 violations
Inspector comments: OSV to pool with Hot Springs Pools and Harkins Builders for return construction. Construction final passed. All items from previous site visit corrected. Permit issued for no night swimming. A follow-up inspection will be conducted by EHS within 30 to 60 days of permit issuance. Ensure log book is provided for follow-up. Holds released in Winchester. Permit sticker provided during the site visit. The State permit will be available online by end of business 10/25.
Note: Mirrors verified with backing tape for restrooms. See permanent file.
Note: All resident rooms that open on to pool deck were verified with window limiters.
Caution: Emergency phone is cellular and not transferring address to 911. The Health Department highly recommends that a phone is installed that can transfer both the address and phone number to 911 for emergency response.
Swimming Pool Permit Restrictions:
1) Pump shall remain at 3450 RPM or flow meter must remain operable with flow at 110 gpm to 138 gpm to meet turnover and flow restriction of suction lines.
Pentair Intelliflo3 VSF 011075, 3 hp pump with (2) Hayward WG1031BHF2 drain covers. (5) skimmers with EQ lines plugged inside and capped on underside.
Max Depth 4 ft.; Pool Width 38 ft.; Rope Length 50 ft.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. Operator had not yet taken over the pool. Ensure daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for cyanuric acid and total alkalinity.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some standing water near shower. Outside of required deck space. If area begins to mildew or becomes a slip hazard, may require repair in future.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “JUNCTION 49 - POOL” or State ID 2060530767). Inspection type (routine vs. follow-up) is not published in the county's data.