6demerits
ABBERLY COMMONS APARTMENTS
5020 JAMES BRADLEY LEE WY, Charlotte, NC 28215
Year-Round Swimming Pool · NC permit/State ID 2060530770
Latest result6 demerits
Last inspectedAug 6, 2026
Inspections on record5
On record sinceOct 16, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Oct 16, 2024Lower is betterAug 6, 2026
Inspections & violations
Aug 6, 2026 6 demerits · 1 violation
Inspector comments: Inspection completed with Jerome Walcott present.
Permit conditions - pump shall remain at 3450 RPM - or - flow meter must remain operable with flow at 87GPM to 138 GPM to meet turnover and flow restriction of the suction lines. Pool not approved for salt as primary chlorination.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 8.4. CDI- adjusted to 7.4.
Mar 10, 2026 4 demerits · 1 violation
Inspector comments: Permit Restrictions:1) Pump shall remain at 3450 RPM or flow meter must remain operable with flow at 87 gpm to 138 gpm to meet turnover and flow restriction of the suction lines.2) Pool is not approved for salt as primary chlorination.
Main Drain covers expire 7/15/2029
Ensure that the landscaping is maintained such that the space under the fence and gates remains at 2 inches or less.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed gaps in the record log. Ensure that all required records are properly kept. No permit action taken, most records were provided.
Sep 15, 2025 0 demerits · 0 violations
Inspector comments: Maintain the rock landscaping under the fence such that there is no more than a 2 inch gap under the fence at any point.
NO VIOLATIONS NOTED.
Permit Restrictions:1) Pump shall remain at 3450 RPM or flow meter must remain operable with flow at 87 gpm to 138 gpm to meet turnover and flow restriction of the suction lines.2) Pool is not approved for salt as primary chlorination
No violations were recorded for this inspection.
Apr 28, 2025 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. POOL HAS PASSED INSPECTION, PREVIOUS ISSUES WERE CORRECTED. ELECTRICAL PERMIT FOR PUMP AND MOTOR SWAP WERE VERIFIED. (COM-ELC-25-000825). MAIN DRAINS EXPIRE 7/15/2029 ACCORDING TO THE APPROVED PDSC FORM.
POOL IS NOT APPROVED FOR NIGHT SWIMMING. POST SIGNAGE INDICATING THE POOL IS CLOSED DUSK TO DAWN.
No violations were recorded for this inspection.
Oct 16, 2024 6 demerits · 1 violation
Inspector comments: Verified PDSC information.
Pool is not approved for night swimming.
Pump at max speed 3450rpm.
Permit Restrictions:
1)Pump shall remain at 3450 RPM or flow meter must remain operable with flow at 87 gpm to 138 gpm to meet turnover and flow restriction of the suction lines.
2)Pool is not approved for salt as primary chlorination.
Permit issued.
#3 · Water quality: pool water pH −6
Observed pH at 7.0 raised to 7.2 during inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ABBERLY COMMONS APARTMENTS” or State ID 2060530770). Inspection type (routine vs. follow-up) is not published in the county's data.