MARLEY APARTMENTS, THE

1100 FALLS CREEK LN, Charlotte, NC 28209
Year-Round Swimming Pool · NC permit/State ID 2060530785
Latest result6 demerits
Last inspectedMar 9, 2026
Inspections on record3
On record sinceMay 21, 2025

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 May 21, 2025: 16Oct 7, 2025: 22Mar 9, 2026: 6
May 21, 2025Lower is betterMar 9, 2026

Inspections & violations

Mar 9, 2026 6 demerits · 2 violations
Inspector comments: Conducted inspection with CPO. 5% compliant flow meter in pump room. Property submitting new PDSC for approval. Pump 1: 75gpm Pump 2: 70gpm 2nd CPO- MANUEL MONTANO PEREZ - mmontanoperez@s2res.com Requires 5% flow meter for 2026 on Upper Pools. Permit Restrictions: 1) Both systems required to have operable flow meters. 2) Pump 1 - Fountain and Lower Pool - Pump shall be kept at 54 gpm to 98 gpm to meet turnover and flow restriction of the filter. Flow greater than 119 gpm exceeds the main drains. Suction Hazard. 3) Pump 2 - Upper Pools - Pump does not meet turnover at 83 gpm due to flow restriction of the number of returns. Flow greater than 119 gpm exceeds main drains. Suction Hazard. Pump required at 80 gpm. Note: (2) stepping stone SDX2 drain covers not operable per Caribbean - no suction. 4 drains in lower pool - 4 drains in upper pools. 10 drains total with 2 not operable. SDX2 drain covers in the stepping stones - installed 6/1/2024. Const. Date: 1/1/1985 Rope Length: 27' Night Swim?: No
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Large gap under part of fence left side of pool. Operator corrected with landscaping .2537(b) All gates and doors shall be self-closing, self-latching. Back pickleball gate not self latching. Operator corrected. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No chemical storage room. Pool exempt due to being built in 1985.

View this inspection on the county portal ›

Oct 7, 2025 22 demerits · 6 violations
Inspector comments: Conducted inspection with operator Immediate suspension issued for chlorine level. Call EHS Devon when ready for re inspection 7049981122. Records, fence, and full skimmers must be corrected upon return or 30 day intent to suspend may be issued. Pump 1: 70gpm Pump 2: 135gpm corrected to 80gpm Note: 3 side gates permanently closed. Operable gates include two entrance gates on either side of clubhouse and back gate leading to pickleball court. Upper structures are fountains. No night swimming Construction Date 1/1/1985 Rope Length 27ft Permit Restrictions: 1) Both systems required to have operable flow meters. 2) Pump 1 - Fountain and Lower Pool - Pump shall be kept at 54 gpm to 98 gpm to meet turnover and flow restriction of the filter. 3) Pump 2 - Upper Pools - Pump does not meet turnover at 83 gpm due to flow restriction of the number of returns. Pump required at 80 gpm. (2) stepping stone SDX2 drain covers not operable per Caribbean - no suction. 2 drains in lower pool - 4 drains in upper pools - 2 drains in small fountain feature are. 10 drains total with 2 not operable. SDX2 drain covers in the stepping stones - installed 6/1/2024.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0ppm. Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records available since late July. Must provide daily and weekly records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers full of leaves and debris. Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Missing end cap on lower ladder. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence detached by body hook creating a 6” opening. Reattach fence post and close gap. Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No chemical storage room. Pool exempt due to being built in 1985.

View this inspection on the county portal ›

May 21, 2025 16 demerits · 4 violations
Inspector comments: Conducted inspection with CPO Manuel. Intent to suspend issued. Intent to suspend items must be fixed prior to June 1st or pool will have to close. Call EHS Devon when ready 7049981122 Note: 3 side gates permanently closed. Operable gates include two entrance gates on either side of clubhouse and back gate leading to pickleball court. Upper structures are fountains. Construction Date 1/1/1985 Rope Length 27ft Permit Restrictions: 1) Both systems required to have operable flow meters. 2) Pump 1 - Fountain and Lower Pool - Pump shall be kept at 54 gpm to 98 gpm to meet turnover and flow restriction of the filter. 3) Pump 2 - Upper Pools - Pump does not meet turnover at 83 gpm due to flow restriction of the number of returns. Pump required at 80 gpm. (2) stepping stone SDX2 drain covers not operable per Caribbean - no suction. 2 drains in lower pool - 4 drains in upper pools - 2 drains in small fountain feature are. 10 drains total with 2 not operable. SDX2 drain covers in the stepping stones - installed 6/1/2024.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4" and shall provide no external handholds or footholds. Two openings greater than 4” at gates on either side of the clubhouse. Old handles on gates (not in use anymore) protrude more than two inches and are below 40” creating footholds. Intent to suspend items.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted callback number incorrect. Verified correct number with emergency department. Operator posted correct number. No permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter on Pump 1 exceeds allowable range. Must be between 54gpm and 98gpm. Flow meter not working on Pump 2 upper pools. Flow meter must remain operational and read at 80gpm. Intent to suspend items.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No chemical storage room. Pool exempt due to being built in 1985.