‹ Back to search

16demerits

WATERFORD SQUARE II APTS.

6410 WATERFORD CREST DRIVE, Charlotte, NC 28226
Year-Round Swimming Pool · NC permit/State ID 2060530786
Latest result16 demerits
Last inspectedMay 19, 2026
Inspections on record2
On record sinceJul 11, 2025

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 Jul 11, 2025: 20May 19, 2026: 16
Jul 11, 2025Lower is betterMay 19, 2026

Inspections & violations

May 19, 2026 16 demerits · 3 violations
Inspector comments: Conducted inspection with CPOs and maintenance crew. Pool placed on A status and is in good standing. Permit Restrictions: Flow meter must remain operable. Flow required at 86 gpm to 104 gpm to meet turnover and flow restriction of return pipe. 2) Main drains must remain disabled due to suction hazard or repaired to meet mfg. specifications. Dummy covers on bottom of pool. Note: Pump aftermarket - same curve as SP3202VSP. Main drains disabled - plugged in sumps and also capped in pump room. Const. Date: 8/18/1995 Rope Length: 50' Night Swim?: N
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0. Operator corrected to 2ppm. No permit action.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Body hook missing. Operator located and replaced. No permit action. .2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope tangled and inaccessible. Operator corrected. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Right side access gate swings towards pool due to gas line limitation. Pre 2010 pool. No permit action.

View this inspection on the county portal ›

Jul 11, 2025 20 demerits · 5 violations
Inspector comments: Inspection completed with Bryan Burch, Dan Duncan, David Gonzalez, Josh Carroll, Nicole Meier present. See below for in field plan review notes. 1) Permit Restrictions: Flow meter must remain operable. Flow required at 86 gpm to 104 gpm. OBSERVED FLOW AT 86GPM 2) Main drains must remain disabled due to suction hazard or repaired to meet mfg. specifications. OBSERVED MAIN DRAIN LINE CAPPED OFF IN PUMP ROOM. 3) New Pump Hayward TristarVS 900 W3SP3202VSP 1.85 THP - VERIFIED AND ACCURATE 4) Verify straight run pipe at >10” inlet and >4” outlet. OBSERVED 24 INCHES AND 18 INCHES. 5) Blue white flow meter reading the range listed above after backwash. FLOW AT 86GPM. 6) Main drain line should be capped in the pump room. VERIFIED AND ACCURATE. 7) (1) 2” main drain line; (1) 2” skimmer line and (1) 2” return line. VERIFIED AND ACCURATE. 8) (2) Paramount SDX2 2017 drain covers no suction. Incorrect. OBSERVED 2 AQUASTAR A10RCFR DRAIN COVERS INSTALLED. RESUBMIT NEW PDSC PAPERWORK FOR APPROVAL WITH UPDATED INFORMATION. 9) (1) Pentair TR140C filter. VERIFIED AND ACCURATE. 10) 6 returns, either on the floor or the wall - VERIFIED AND ACCURATE. 11) (3) skimmers plugged per State requirement. VERIFIED AND ACCURATE. CPO is Dan Duncan. CPO # is C-093354
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one damaged overflow grate. Replace or permit may be suspended.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed 2 body hooks at pool. One body hook had a pole at length less than 12 feet. CDI- pole and hook removed from property. The other body hook with pool remains on pool deck and is in compliance. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 55 feet. CDI- adjusted to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self-latching. CDI- repaired.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed signage in less than 1 inch letter. CDI- new sign provided and in compliance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Low lighting in pump room.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WATERFORD SQUARE II APTS.” or State ID 2060530786). Inspection type (routine vs. follow-up) is not published in the county's data.