4demerits
704 AT THE QUARTER
704 W TREMONT AV, Charlotte, NC 28203
Year-Round Swimming Pool · NC permit/State ID 2060530787
Latest result4 demerits
Last inspectedAug 13, 2026
Inspections on record4
On record sinceMay 8, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 8, 2025Lower is betterAug 13, 2026
Inspections & violations
Aug 13, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Caleb.
Gaps greater than 1/2” within 18” of the gate latch shall be corrected before next routine inspection.
Several potential footholds present on outside of fence in grill area. These are not attached to the pool fence. Recommend moving footholds or extending fence height with a barrier. Shown to CPO and property manager.
Requires 5% flow meter for 2026. PDSC form missing flow reduction - required for 2026.Permit Restriction: Flow meter must remain operable. Pump flow must be at least 45 gpm for turnover and cannot exceed 98 gpm for filter limitation. Flow greater than 138 gpm for filtration exceeds the main drains. Suction Hazard Const. Date: 2/2/2025 Rope Length: 38' Night Swim?: No
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Two gates have gaps greater than 1/2” within 18 inches of the latch. Shown to CPO and property manager during the inspection. This shall be in compliance before next inspection. No permit action at this time.
Mar 25, 2026 4 demerits · 1 violation
Inspector comments: Performed inspection with CPO Caleb. Intent to suspend issued for inoperable flow meter. Item must be corrected within 30 days or permit may be suspended. Call Devon when complete 7049981122.
Requires 5% flow meter for 2026. PDSC form missing flow reduction - required for 2026.Permit Restriction: Flow meter must remain operable. Pump flow must be at least 45 gpm for turnover and cannot exceed 98 gpm for filter limitation. Flow greater than 138 gpm for filtration exceeds the main drains. Suction Hazard
Const. Date: 2/2/2025 Rope Length: 38' Night Swim?: No
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Flow meter observed to be not operational. Flow meter must remain operational. Flow meter must be replaced with a 5% accurate flow meter.
Permit Restriction: Pump flow must be at least 45gpm for turnover and cannot exceed 98gpm for filter limitation.
Intent to suspend item.
Jul 8, 2025 14 demerits · 3 violations
Inspector comments: Conducted inspection with CPO Jorge.
Immediate suspension issued for low chlorine level. Pool must close.
Flow meter and records must be corrected prior to site visit or an intent to suspend may be issued.
Call EHS Devon when items are corrected and pool is ready to reopen. 7049981122
Permit Restriction: Pump flow must be at least 45gpm for turnover and cannot exceed 98gpm for filter limitation
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0ppm. Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Observed missing daily drain checks and weekly CA and TA records. Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter observed to be not operational. Flow meter must remain operational.
Permit Restriction: Pump flow must be at least 45gpm for turnover and cannot exceed 98gpm for filter limitation.
Intent to suspend item.
May 8, 2025 0 demerits · 0 violations
Inspector comments: Observed no non-compliant items.
Permit Restriction: Pump flow must be at least 45gpm for turnover and cannot exceed 98gpm for filter limitation.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “704 AT THE QUARTER” or State ID 2060530787). Inspection type (routine vs. follow-up) is not published in the county's data.