‹ Back to search

4demerits

LINK APARTMENTS NODA 36TH II

3520 PHILEMON AV, Charlotte, NC 28206
Year-Round Swimming Pool · NC permit/State ID 2060530792
Latest result4 demerits
Last inspectedSep 30, 2026
Inspections on record4
On record sinceApr 4, 2025

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Apr 4, 2025: 0Jul 21, 2025: 8Apr 1, 2026: 0Sep 30, 2026: 4
Apr 4, 2025Lower is betterSep 30, 2026

Inspections & violations

Sep 30, 2026 4 demerits · 1 violation
Inspector comments: Inspection completed with James Allen present. Note- emergency phone number posted faded and not legible. CDI- re-wrote phone number on sign using permanent marker. Permit conditions - filtration pump flow meter must remain operable. Flow shall be kept at 44 to 98 GPM to meet turnover and flow restriction of the filter. Feature pump flow meter shall remain operable with flow not to exceed 62 GPM due to flow restriction of suction line OR pump shall be set at 1000 RPM or less. Intent to suspend permit issued for ‘residential use only’ flow meter installed on feature pump and circulation pump. Correct within 30 days or permit may be suspended.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) The flow meter installed shall be accurate to 10% to ensure permit restrictions are met. Observed ‘residential use only’ flow meter installed on main pump and feature pump. Intent to suspend permit issued.

View this inspection on the county portal ›

Apr 1, 2026 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED POOL IS NOT APPROVED FOR NIGHT SWIMMING. MAIN DRAINS EXPIRE 5/1/2029 PERMIT RESTRICTIONS: 1) FILTRATION PUMP-FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE KEPT AT 44 GPM TO 98 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE FILTER. 2)FEATURE PUMP-EITHER FLOW METER SHALL REMAIN OPERABLE WITH FLOW NOT TO EXCEED 62 GPM DUE TO FLOW RESTRICTION OF SUCTION LINE-OR-PUMP SHALL REMAIN SET AT 1000 RPM OR LESS. 3) DICHLORINATION UNIT REQUIRED ON BACKWASH PER CODE ENFORCEMENT. 4) PORTABLE VACUUM REQUIRED

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 21, 2025 8 demerits · 2 violations
Inspector comments: Ensure that the automatic chemical feeding system shuts off automatically if there is no flow in the system, such as from a pump failure. Observed the pool sign to give the pool hours as 8am-8pm. The pool does not have a night swimming approval from the Health Department so it cannot be open after sunset or before sunrise. Ensure the sign does not indicate the pool is open before dawn, or after dusk. “Pool Open Dawn to Dusk” is suggested. PERMIT RESTRICTIONS: 1) FILTRATION PUMP-FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE KEPT AT 44 GPM TO 98 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE FILTER. 2)FEATURE PUMP-EITHER FLOW METER SHALL REMAIN OPERABLE WITH FLOW NOT TO EXCEED 62 GPM DUE TO FLOW RESTRICTION OF SUCTION LINE-OR-PUMP SHALL REMAIN SET AT 1000 RPM OR LESS. 3) DICHLORINATION UNIT REQUIRED ON BACKWASH PER CODE ENFORCEMENT. 4) PORTABLE VACUUM REQUIRED Contact C. Elmore at 704-507-6814 when corrections are made.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed the door leading form the lounge to the pool area to self-close, but not to reliably self-latch. The door must be either fully self-closing and self-latching, or be audibly alarmed to alert whenever the door is opened. I.T.S. Issued. Deadline for correction is 8/20/2025. Failure to correct the item by the deadline may result in the closure of the pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meters no feature system not operational. Flow meter must work or feature pump must be set at no more than 1000 RPM. It was at 1500 RPM upon arrival. Added to I.T.S. Deadline is 8/20/2025.

View this inspection on the county portal ›

Apr 4, 2025 0 demerits · 0 violations
Inspector comments: Observed no non-compliant items Note: Emergency phone cannot be called back with Verizon phone. Permit Restrictions: 1)Filtration Pump Flow meter must remain operable. Flow shall be kept at 44 gpm to 98 gpm to meet turnover and flow restriction of the filter. 2)Feature Pump Either flow meter shall remain operable with flow not to exceed 62 gpm due to flow restriction of suction line. or Pump shall remain set at 1000 RPM or less. 3)Dichlorination unit required on backwash per Code Enforcement. 4)Portable vacuum required. 5)Salt is not approved as primary chlorination.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LINK APARTMENTS NODA 36TH II” or State ID 2060530792). Inspection type (routine vs. follow-up) is not published in the county's data.