18demerits
CHARLOTTE CHRISTIAN SWIM AND RACQUET
7823 SARDIS RD, Charlotte, NC 28270
Year-Round Swimming Pool · NC permit/State ID 2060530815
Latest result18 demerits
Last inspectedAug 6, 2026
Inspections on record3
On record sinceSep 25, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 25, 2025Lower is betterAug 6, 2026
Inspections & violations
Aug 6, 2026 18 demerits · 6 violations
Inspector comments: Send verification of lighting at night to Marie Daley at 704-507-6806 for night swimming which has been approved.
Flow must be maintained at least 446 gpm for turnover. When bubble is placed over pool, ensure signage is visible upon entry and permanently affixed. 2 sets of safety equipment required.
Inspection with Jeremy Mendoza, Grant Guillard, Jonathan Jones
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some minor debris/leaves covering main drain at time of inspection.
.2537(14) Keep pool surface and pool floor free of debris to clearly see main drains. Operator cleaned and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Front gate not closing or latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Gate adjusted to Self-close, self-latch.
Old fencing, original construction with gap by clubhouse with horizontals less than 45” inches height, built 1978.
.2528(a) Horizontals shall not be located less than 45" in height.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare basket for feature pump, Hayward Tristar VS 950, SP32950VSP. .2518(e) Provide a spare basket for pump. Operator corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some equipment within 3’ of piping in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms observed without toilet paper in women’s, without hand drying in men’s.
.2526(l) Provide toilet paper and dispensers in restrooms. Provide hand drying.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Men’s restroom floor holding water, not draining at time of inspection. .2526(c) Restroom floor shall be sloped to drain.
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
Feb 5, 2026 0 demerits · 0 violations
Inspector comments: Inspection completed with Grant Guittard and Jeremy Mendoza present.
Permit conditions/restrictions- flow required to be maintained at a minimum of 446 GPM to meet turnover.
Note- maintain safety signage inside pool enclosure (bubble) when enclosure is in place.
No violations were recorded for this inspection.
Sep 25, 2025 6 demerits · 2 violations
Inspector comments: OSV to pool with Peter Perers and Jeff Gaeckle, CPM. Pool renovation includes - Increase in footprint, decrease in depth, new skimmers, new returns and drain covers with the addition of an aeration system. Pump room/restrooms existing. New pumps in pump room. All items from previous inspection corrected except for final close-out paperwork.
Permit issued. State permit will be posted online by end of business 9/25. Local permit already provided. Holds released.
Max Depth 5 ft.; Pool Width 80 ft.; Rope Length 50 ft.
Permit Restriction: Flow required at least 446 gpm to meet turnover.
Note: Two sets of safety equipment required due to size of pool.
Filtration - Hayward HCP 4000 Series HCP401253, 12.5 hp pump with (2) Aquastar 2017 P18xxx drain covers. EQ lines plugged per State requirement.
Aerator Hayward TristarVS 950 SP32950VSP, 2.7 THP pump with (2) Aquastar 2017 12MFxxx drain covers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Table outside of pool deck next to back gate. Moved during the inspection. Ensure no furniture directly next to the barrier.
Barrier at weight room building and storage building with horizontals on exterior and <45" apart. Fence part of original fence and built pre-2010. Ensure 45" between horizontals.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib or floor drain in weight room restrooms. Original construction. Restrooms shall have floor drain and hose bib.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CHARLOTTE CHRISTIAN SWIM AND RACQUET” or State ID 2060530815). Inspection type (routine vs. follow-up) is not published in the county's data.