4demerits
TRITON UPTOWN
900 N TRYON ST, Charlotte, NC 28206
Year-Round Swimming Pool · NC permit/State ID 2060530830
Latest result4 demerits
Last inspectedJul 7, 2026
Inspections on record2
On record sinceMay 22, 2026
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 22, 2026Lower is betterJul 7, 2026
Inspections & violations
Jul 7, 2026 4 demerits · 1 violation
Inspector comments: -POOL IS NOT APPROVED FOR NIGHT SWIMMING. POOL CANNOT BE OPEN FOR SWIMMING AFTER DUSK OR BEFORE DAWN.
-MAIN DRAINS EXPIRE 10/4/2030
-ENSURE THAT THE GAPS UNDER THE FENCE AND GATES STAY AT 2 INCHES OR LESS.
-OBSERVED MIRRORS IN THE BATHROOMS INSTALLED WITHOUT THE PRIOR APPROVAL. CONTACT THE DEPARTMENT AT 980-314-1620 AND PROVIDE KATIE RUDISILL OR WILL HARRISON WITH THE DOCUMENTATION OF SHOW THAT THE MIRRORS ARE SHATTER PROOFED PRIOR TO INSTALLATION. MIRRORS WERE REMOVED DURING THE INSPECTION. DO NOT PUT THEM BACK UP UNTIL THEY ARE APPROVED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door that leads onto the pool enclosure from the parking deck to be damaged such that it does not latch properly. Door was corrected during inspection.
May 22, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with Brian Yarmon, Connor Construction, and CPO with Queen City Pool Services.
All items from construction have been addressed.
Conducted pre-permit inspection.
Permit Restriction: Flow meter must remain operable. Flow required no greater than 258 gpm due to drain cover flow restriction. Suction Hazard.
Minimum turnover is 155 gpm. Verified at 160 GPM after a backwash.
Records not yet being kept. Ensure checking daily chlorine, pH, main drains, and temperature when heater is on. Check at least weekly total alkalinity and cyanuric acid.
Pool needs 8 feet of deck clearance.
Max Depth 4 ½ ft.; Pool Width 58 ft.; Rope Length 50 ft.
Filtration: Hayward HCP 3000 Series HCP30503, 5 hp pump with (2) Aquastar 9MFxxx 2017 drain covers. EQ lines capped on underside and plugged in skimmer.
Feature: Hayward HCP2000 Series HCP20153, 1.5 hp pump with (2) Aquastar 9MFxxx 2017 drain covers.
Note: No mirrors in restrooms. If installed, mirrors shall be shatterproof. Provide product spec sheet to health department for approval prior to installation.
Permit issued with the following conditions
No night swimming
Maintain flow meter operational and between 155 GPM and 258 GPM for minimum turnover and flow restriction of the main drains.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap greater than 2” under some patio fencing. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “TRITON UPTOWN” or State ID 2060530830). Inspection type (routine vs. follow-up) is not published in the county's data.