Jul 22, 2026 10 demerits · 2 violations
Inspector comments: Inspection completed with Kaudifee Thompson present.
Permit conditions- pool pump flow rate must be between 75 GPM and 138 GPM for main drain and skimmer piping limitation.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Observed chlorine at 0ppm. CDI- adjusted to 2.0ppm through use of automatic feeder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Observed one door at back of pool not self-latching. CDI- repaired.
Feb 10, 2026 2 demerits · 1 violation
Inspector comments: Permit Restriction: Pool pump flow must be at least 75gpm and cannot exceed 138gpm for main drain and skimmer piping limitation.Note: Clearance between pool pump and backwash pit at 27” points will be taken on inspections.
Pool not approved for night swimming.
Main drains expire 10/28/2030
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed 27" of clearance between equipment and backwash pit.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Dec 9, 2025 2 demerits · 1 violation
Inspector comments: Permit Restriction: Pool pump flow must be at least 75gpm and cannot exceed 138gpm for main drain and skimmer piping limitation.
Note: Clearance between pool pump and backwash pit at 27”, points will be taken on inspections.
DOL inspection for pool heater not completed. Pool is not permitted to use heater until inspection has occurred and the Health Department has been provided notice of passing inspection. Notify the Health Department of any changes in installation.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed 27" of clearance between equipment and backwash pit.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.