‹ Back to search

0demerits

YARDLY CITY PARK

1505 SPLASH PAD CT, Charlotte, NC 28217
Year-Round Swimming Pool · NC permit/State ID 2060530835
Latest result0 demerits
Last inspectedAug 27, 2026
Inspections on record3
On record sinceFeb 12, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Feb 12, 2026: 4Mar 11, 2026: 0Aug 27, 2026: 0
Feb 12, 2026Lower is betterAug 27, 2026

Inspections & violations

Aug 27, 2026 0 demerits · 0 violations
Inspector comments: No violations were observed during today's routine inspection. Inspection conducted with CPO Nick. PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW REQUIRED AT 91 GPM TO 95 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF SKIMMER LINE (SKIMMER LINE NOT PLUMBED PER PLAN). NOTE: NO CATCH DRAIN ON CHECK VALVE FOR FILL LINE DUE TO SLOPE OF FLOOR IN PUMP ROOM. No night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 11, 2026 0 demerits · 0 violations
Inspector comments: Follow-up inspection. Conducted inspection with CPO Christian. Pool remains on A status and in good standing. Permit Restriction: Flow meter must remain operable. Flow required at 91 gpm to 95 gpm to meet turnover and flow restriction of skimmer line (skimmer line not plumbed per plan). Note: No catch drain on check valve for fill line due to slope of floor in pump room. Const. Date: 11/30/2025 Rope Length: 30' Night Swim?: No

No violations were recorded for this inspection.

View this inspection on the county portal ›

Feb 12, 2026 4 demerits · 1 violation
Inspector comments: Onsite visit to pool for return construction/operating permit with Nicholas Denton. All items from previous site visit corrected. Construction final passed. Holds released. Operating permit issued. Permit Restriction: 1)Flow meter must remain operable. Flow required at 91 gpm to 95 gpm to meet turnover and flow restriction of skimmer line (skimmer line not plumbed per plan). Notes: 1)5 ½ ft. on right side of pool with no depth marker on deck. <25 ft. between other depth markers, not required. Recommend installing on deck. 2)No catch drain on check valve for fill line. Floor in pump room slopes to center drain. Jandy VSPlus HP VSPHP270DV2A, 2.7 THP pump with (2) Aquastar WAV12WRxxx 2017 drain covers installed. EQ lines plugged in skimmer/capped on underside. Local permit sticker was issued while onsite. The State permit will be posted online by end of business. A follow-up, unannounced inspection will be completed within 30 to 60 days.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump running at 105 gpm. Adjusted to 95 gpm during the inspection to meet permit restriction. Ensure pump set to 91 gpm to 95 gpm.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “YARDLY CITY PARK” or State ID 2060530835). Inspection type (routine vs. follow-up) is not published in the county's data.