‹ Back to search

10demerits

EASTON AT MOUNTAIN ISLAND

6015 MAR DHEA LN, Charlotte, NC 28214
Year-Round Swimming Pool · NC permit/State ID 2060530867
Latest result10 demerits
Last inspectedAug 24, 2026
Inspections on record2
On record sinceJul 2, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Jul 2, 2026: 8Aug 24, 2026: 10
Jul 2, 2026Lower is betterAug 24, 2026

Inspections & violations

Aug 24, 2026 10 demerits · 2 violations
Inspector comments: Inspection conducted with Anthony Carrera and Deandre Fogle. Permit immediately suspended for disinfectant residual. Need a minimum of 1.0ppm of chlorine. Call inspector Kurtis Nelson when in compliance. 980-378-7896 Permit Restriction: Filtration pump flow meter must remain operable. Flow required at 116 gpm to 138 gpm to meet turnover and flow restriction of the suction piping. Pool Width 30 ft.; Rope Length 45 ft.; Max Depth 5 ft. on center. Filtration Pentair Intelliflo3 VSF 011075, 3 hp with (2) Hayward WG1032BHF2 drain covers. EQ lines plugged in skimmer. Feature Pentair Superflo VST 342002, 1.5 hp.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. 0ppm of chlorine was observed. Permit is suspended.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Some skimmers had debris. All cleaned during inspection. CDI

View this inspection on the county portal ›

Jul 2, 2026 8 demerits · 2 violations
Inspector comments: OSV to pool with Mason Garrett, Hot Springs Pools. Items from previous site visit correct. Lights removed with cap installed over top. Lights to be moved across sidewalk to eliminate horizontal 45" issue. Current caps not <45" to next horizontal on barrier. Permit issued for no night swimming. A follow-up inspection will be completed within 30-60 days of permit issuance. State permit will be posted online by end of business. Pergola built and did not go through plan approval. Pergola blocked off with construction fence. Provide permit numbers. Permits shall be finaled prior to usage. Contractor stated plans were not submitted. Note: 1) Backwash pit built up with walls. Not leaking at time of inspection. Ensure no leaks with backwash. Property still waterproofing the pit. 2) Previous site visit had standing water at corners of deck near landscape on both sides closest to clubhouse. Deck dry. Did not appear to have staining. If standing water an issue after rain event, will require repair in the future. 3) No handles on gates. If installed, ensure 45” from ground. Permit Restriction: Filtration pump flow meter must remain operable. Flow required at 116 gpm to 138 gpm to meet turnover and flow restriction of the suction piping. Pool Width 30 ft.; Rope Length 45 ft.; Max Depth 5 ft. on center. Filtration Pentair Intelliflo3 VSF 011075, 3 hp with (2) Hayward WG1032BHF2 drain covers. EQ lines plugged in skimmer. Feature Pentair Superflo VST 342002, 1.5 hp. Tied into same set of main drains as the filtration system. Backwash line, during backwash, with water hitting drain line for check valve. Move lines to eliminate splash prior to follow-up inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drain checks not recorded daily. Maintain daily record keeping for main drain checks.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Filter pressure gauge not operable. Contractor replaced and provided pictures or operable pressure gauge.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “EASTON AT MOUNTAIN ISLAND” or State ID 2060530867). Inspection type (routine vs. follow-up) is not published in the county's data.