20demerits
GRAHAM HOUSE
312 N GRAHAM ST, Charlotte, NC 28202
Year-Round Swimming Pool · NC permit/State ID 2060530872
Latest result20 demerits
Last inspectedAug 17, 2026
Inspections on record2
On record sinceJul 2, 2026
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 2, 2026Lower is betterAug 17, 2026
Inspections & violations
Aug 17, 2026 20 demerits · 4 violations
Inspector comments: -PERMIT CONDITION NOT MET-
Observed flowmeter reading at gpm of 120. Permit restricts flow from 46-80 gpm.
Pentair Intelliflo3 VSF 011076, 3 hp pump. Pool built without main drains.
PERMIT CONDITIONS:
1. Flow meter must be operable. Flow required at 46 gpm to 80 gpm to meet turnover and flow restriction of number of returns.
2. Portable vacuum required. Pool built without vacuum line.
3. Sump pump required. No main drains.
Max depth 4 ft. Pool Width 23 ft. Rope length 35 ft.
Immediate Suspension Issued:
Failure to maintain proper chlorine and pH levels.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
Observed chlorine at 0 PPM during inspection.
Recommend getting auto-chemical feeder calibrated. No direct chlorination allowed.
-Immediate Suspension Issued-
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH below 7.0 (kit reads to 7.0)
Recommend getting auto-chemical feeder calibrated.
-Immediate Suspension Issued-
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed shepherds hook attachment on the ground at the start of the inspection. Skimmer net was attached to the pole.
-CDI- CPO reattached body hook attachment properly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
Observed Pump room wet with puddles of standing water.
Ensure maintained dry and free of standing water.
Jul 2, 2026 6 demerits · 2 violations
Inspector comments: OSV to pool for return construction. All items from previous site visit corrected. All permits finaled. Holds removed from the project. Permit issued for no night swimming.
Noah Johnson, CPO, and Mark Adams, ADA Pools, present during the inspection.
Note: Operator added shock before the inspection. Chlorination must occur through the feeder. Verified the feeder and reading what chemicals obtained in the pool. Pool shall not be open if pool chlorine is less than 1 ppm.
Pentair Intelliflo3 VSF 011076, 3 hp pump. Pool built without main drains.
Permit Restrictions:
1) Flow meter must remain operable. Flow required at 46 gpm to 80 gpm to meet turnover and flow restriction of the number of returns.
2) Portable vacuum required. Pool built without vacuum line.
3) Sump pump required. No main drains.
Max Depth 4 ft.; Pool Width 23 ft.; Rope Length 35 ft.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CYA not recorded weekly. Record weekly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to water chemical testing. Keep floor dry.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GRAHAM HOUSE” or State ID 2060530872). Inspection type (routine vs. follow-up) is not published in the county's data.