‹ Back to search

38demerits

LANDON II, THE

8200 RIVERBIRCH DR, Charlotte, NC 28210
Year-Round Swimming Pool · NC permit/State ID 2060530874
Latest result38 demerits
Last inspectedAug 18, 2026
Inspections on record1
On record sinceAug 18, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Inspections & violations

Aug 18, 2026 38 demerits · 9 violations
Inspector comments: Seasonal to annual permitting inspection by request of property. Pool has not been permitted this season. Permit not issued. Repair listed items and call EHS Devon when ready for re inspection 7049981122. SDX COVERS ON WALL VERIFIED NO SUCTION Rope Length: 50ft Night Swimming: No
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. EHS observed chlorine at 0ppm.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. EHS observed pH at less than 6.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 2 weirs missing. Replace. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris outside of skimmer basket and settled at bottom of skimmer units. Clean out.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. All rubber end caps on ladders missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope detached from ring buoy rope and incorrect length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate that allows passage of a four inch diameter sphere. Over 4” opening between fence end of fences at building sides. Cover opening. .2528(a) Gate latches shall be 54" in height. Gate latch by pump room not 54” in height. Raise. .2537(b) All gates and doors shall be self-closing, self-latching. Gate by pump room not self closing self latching. Repair. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Windows onto pool deck from club house open all the way. Install limiters. .2528(b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010). Foothold where fence connects to clubhouse. .2528(a) Solid barriers that do not have openings shall contain no indentations or protrusions (greater than 1/2") except for normal construction tolerance . Foothold where fence connects to clubhouse. Install slanted piece to eliminate foothold.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Incorrect rule wording. Replace sign.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Flow meter not operational. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Pool built in 1984.