0demerits
FAIRWAYS AT PIPER GLEN
6200 BIRKDALE VALLEY DR, Charlotte, NC 28277
Year-Round Spa · NC permit/State ID 2060550089
Latest result0 demerits
Last inspectedJul 28, 2026
Inspections on record14
On record sinceNov 19, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Nov 19, 2014Lower is betterJul 28, 2026
Inspections & violations
Jul 28, 2026 0 demerits · 0 violations
Inspector comments: Conducted inspection with property manager Corey. Pre 2010 fencing. Spa remains in good standing and on A status.
Ensure numerical temperature of spa is recorded daily.
Jet pump: 60gpm
Permit Restrictions: 1) Filtration flow meter must remain operable. Flow shall not exceed 119 gpm due to drain cover flow restriction. Suction Hazard. Minimum turnover is 54 gpm. 2) Jet flow meter must remain operable. Flow shall not exceed 119 gpm due to drain cover flow restriction. Suction Hazard.
Const. Date: 6/28/1995
Night Swim?: N
No violations were recorded for this inspection.
May 20, 2026 8 demerits · 2 violations
Inspector comments: Inspection completed with Juan Miranda, Dan Duncan, and Corey Gallian present.
Note- bonding wire could not be located for the spa jet pump. The facility has agreed to maintain the spa jet pump OFF until a bonding wire is installed and an electrical inspection is completed.
Permit conditions- Filtration flow meter must remain operable. Flow shall not exceed 119 GPM due to drain cover flow restriction. Suction hazard. Minimum turnover is 54 GPM. Jet flow meter must remain operable. Flow shall not exceed 119 GPM due to drain cover flow restriction. Suction hazard.
#14 · Pool maintenance: spa timer working properly −4
.2537(b) Spa times shall not exceed 15 minutes without manual resetting. Observed spa timer at approximately 19 minutes duration. Spa heater is currently turned off. Facility has also agreed to maintain spa jet pump off due to a missing ground/bond wire. No permit action taken.
#20 · Premises: caution signs posted at hot water spas −4
.2532(15) Provide Caution sign in 1/2" lettering with exact wording. Observed sign that should read ‘keep all breakable objects out of the area’ instead displayed as ‘no glass or breakable objects out of the area.’ Spa heater is currently not functional and is therefore disabled. Spa sign must be corrected prior to turning on the heater for the spa. No permit action taken.
Jul 18, 2023 16 demerits · 5 violations
Inspector comments: Issued permit. No Night Swimming.
Pump missing placard, motor observed 3HP (rather than 2 HP). Referring to Code for electrical permit, not found in system for motor change out.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Operator drained added water and adjusted to 8 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid missing on records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. No 3’ clearance. Pool built 95 .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Piping missing labels. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash.
.2513(b) Filter backwash shall be discharged through an air gap.
Apr 29, 2022 4 demerits · 1 violation
Inspector comments: Inspection completed with Juan Miranda present.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door at gym leading onto pool deck not self-latching. CDI- repaired.
Sep 17, 2021 4 demerits · 1 violation
Inspector comments: Inspection completed with Juan and Brian Burch present. No signature due to COVID.
Observed bonding wire not affixed to pump. CDI- bonding wire was affixed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate located nearest the gazebo not self-latching. CDI- gate adjusted to be self-latching.
Mar 9, 2020 14 demerits · 3 violations
Inspector comments: Permit suspension for chlorine at 0.0ppm.
ITS will be issued for NO RECORD KEEPING & MISSING FITTINGS if these items are not corrected on or before the permit suspension is lifted.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.0ppm. Permit suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no written records for 2020 operating year. Intent to suspend the permit will be issued for this violation if it is not corrected when the permit suspension is lifted.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 missing fittings on spa wall. Intent to suspend the permit will be issued for this violation if it is not corrected when the permit suspension is lifted.
Aug 5, 2019 8 demerits · 2 violations
Inspector comments: SPA NOT APPROVED FOR NIGHT SWIMMING. DAWN TO DUSK ONLY. CONTACT C. ELMORE IF NIGHT SWIMMING IS DESIRED SO THAT EVALUATION FOR NIGHT SWIMMING CAN BE SCHEDULED.
C. ELMORE 704-507-6814
PERMIT WILL BE ISSUED. STICKER ISSUED.
SPA MAY OPEN FOR SWIMMING.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
OBSERVED FENCE NOT TO CURRENT RULES. GAPS GREATER THAN 4" NOTED. NO PERMIT ACTION TAKEN. FENCE BUILT PRIOR TO 2010.
#14 · Pool maintenance: spa timer working properly −4
OBSERVED SPA TIMER TO RUN FOR 22 MINUTES. TIMER MUST RUN JETS FOR 15 MINUTES OR LESS. TIMER CORRECTED TO 12 MINUTES.
Nov 30, 2017 32 demerits · 8 violations
#3 · Water quality: pool water pH −6
Obseved pH to be 6.8 or less. pH must be 7.2-7.8 for safety. PERMIT SUSPENDED SPA CLOSED TO SWIMMING
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily and weekly log records not properly kept. Daily and weekly checks must be performed and logged every day the pool/spa is open for use. This includes weekends and holidays if the pool/spa is open for use. The CPO must observed the pool/spa every day it is open for use.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed EQ cover missing from skimmer line. Observed pump information on PDSC form to be incorrect. Filtration system appears to be a WFE-8 2HP pump while Jets are a Hayward RS2000. This is not reflected in what has been submitted to the Health Department. Replace the EQ line cover with appropriate cover and submit new corrected PDSC forms to the Health Department for approval. PERMIT SUSPENDED SPA IS CLOSED TO SWIMMING.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed fittings missing from returns/jets inside the spa. Replace the fittings.
#14 · Pool maintenance: spa timer working properly −4
Observed spa timer damaged, unable to test timer. Repair timer and ensure it activates jets for no longer than 15 minutes at a time.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed floor of pump room wet from possible leak. Fix any leaks. Observed chemical in open paper bag stored on the floor. Do not store such items on the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at the backwash line.
Apr 12, 2017 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep pool floor free of debris. Observed what looked to be sand on spa floor.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room door unlocked. Pumproom door should be locked when not in use. Also observed water on pump room floor repair leak.
Dec 13, 2016 20 demerits · 5 violations
Inspector comments: issued immediate suspenstion for #2
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in spa. Masintain at least 1.0ppm in spa.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily written records not being maintained. Keep daily written records for pH, chlorine and main drain safety. Keep weekly written records for total alkalinity and cyanuric acid.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves and debris in spa. Keep spa free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer was full of leaves. Keep skimmers free of debris.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light oput in chemcala room. Also observed spilled sodium bicarbonate in chemical room. Clean up chemical room.
Mar 15, 2016 6 demerits · 1 violation
Inspector comments: Immediate suspension for # 3. Volume on emergency phone was very low. Consider correcting issue.
#3 · Water quality: pool water pH −6
Obsevred pH at 7.0. Maintain pH between 7.2 and 7.8
Oct 15, 2015 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH at 6.8. pH must be maintained between 7.2 and 7.8
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records. Maintain daily records for pH, chlorine and main drain safety. Maintain weekly records for total alkalinity and cyanuric acid.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
•Observed water on pump room floor repair leak.
May 27, 2015 22 demerits · 5 violations
Inspector comments: G.C. Observed hydrotherapy system not working. Repair it and ensure that it operates for no more than 15 minutes at a time. Post permit in the pool area in public view.
#2 · Water quality: disinfectant residual provided by −6
Observed 0.0ppm cl2 in Spa. I.S. Issued. Spa must have at least 1.0ppm cl2 residual. Spa must be closed to swimming.
#3 · Water quality: pool water pH −6
Observed less than 6.8 for pH. pH must be 7.2-7.8 for safe swimming. I.S. Issued. Spa must be closed to swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed sand in spa. Keep spa clean.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed floor of pump room wet. Keep the floor dry and fix any leaks.
Nov 19, 2014 24 demerits · 6 violations
Inspector comments: -GC-14. Observed hydrotherapy system not working. Repair it and ensure that it operates for no more than 15 minutes at a time. 20. Observed spa sign not to have the required word "CAUTION" in 1/2 inch letters. Provide required wording in properly sized letters.
#3 · Water quality: pool water pH −6
pH was found to be 7.0. pH must be 7.2-7.8. -IS- Issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed sand in spa. Keep spa clean.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed broken eyeball fitting. Repair it.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed.gates not self-closing/self-latching fully. Gates must fully self-close and self-latch.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed leak at filter. Observed flow meter stuck. Repair these items.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed floor wet from leak.