‹ Back to search

6demerits

DRURY INN & SUITES SPA

415 W W T HARRIS BLVD, Charlotte, NC 28262
Year-Round Spa · NC permit/State ID 2060550095
Latest result6 demerits
Last inspectedJan 6, 2026
Inspections on record28
On record sinceSep 11, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Sep 11, 2013: 6Mar 12, 2014: 6Mar 24, 2014: 18Oct 15, 2014: 14Feb 11, 2015: 12Sep 24, 2015: 6Sep 25, 2015: 0Jan 20, 2016: 14Nov 29, 2016: 10Mar 21, 2017: 4Oct 23, 2017: 6Feb 5, 2018: 14Nov 19, 2018: 6Jan 14, 2019: 2Nov 5, 2019: 22Feb 25, 2020: 6Nov 17, 2020: 22Jan 20, 2021: 0Dec 16, 2021: 6Jan 11, 2022: 6Nov 3, 2022: 12Jan 5, 2023: 2Nov 15, 2023: 0Feb 1, 2024: 10Dec 3, 2024: 16Jan 6, 2025: 0Aug 5, 2025: 6Jan 6, 2026: 6
Sep 11, 2013Lower is betterJan 6, 2026

Inspections & violations

Jan 6, 2026 6 demerits · 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed missing screw on one drain cover. Corrected onsite. .2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used.

View this inspection on the county portal ›

Aug 5, 2025 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Adjusted onsite to 7.5 .2535(1) Maintain pH at 7.2 to 7.8.

View this inspection on the county portal ›

Jan 6, 2025 0 demerits · 0 violations
Inspector comments: Missing weir in skimmer has been replaced. No other violations observed. Intent to suspend lifted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 3, 2024 16 demerits · 3 violations
Inspector comments: Issued intent to suspend for missing weir. Please replace missing weir within 30 days and call James.Bjorneboe at 704-507-6820 to schedule re-visit once repairs are made. Inspection led by Maddie Denoncour
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Adjusted to 7.2 onsite. .2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed only weir in spa missing. Replace missing weir. ITS item. .2518(k) Replace missing weirs.
#22 · Premises: emergency telephone provided −6
No phone number posted at emergency phone. Corrected on site. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.

View this inspection on the county portal ›

Feb 1, 2024 10 demerits · 2 violations
Inspector comments: Issued intent to suspend for missing daily records (.2535)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records. Maintain daily/weekly records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#22 · Premises: emergency telephone provided −6
Observed inoperable emergency phone. Corrected on site. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.

View this inspection on the county portal ›

Nov 15, 2023 0 demerits · 0 violations
Inspector comments: Spa moved from E to A status as the expired drain covers have been replaced and an updated PDSC form has been completed and approved by the Health Department. Feature jet pump is currently disconnected. Jets are using air pump only at this time. Prior to reconnecting jet pump, facility must submit updated PDSC form and have approval from Health Department. Inspection completed with Jordan Johnson, Stacie, and maintenance supervisor, Donnie.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jan 5, 2023 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak near spa filter. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals stored in the pump room..2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Liquid acid for automatic feeder stored in a bucket labeled as containing bromine. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.

View this inspection on the county portal ›

Nov 3, 2022 12 demerits · 3 violations
Inspector comments: Inspection conducted with inspector Hannah Howard and CPO Steven Hoyt. Labels not observed on spa pumps. Verified that pumps are Sta-Rite pumps with 2 HP motors. Spa jets currently not working. Issue with pump motor. If motor replaced, will need an electrical permit and passing inspection from Mecklenburg County Code Enforcement. Was not able to test spa jets. Ensure that jets shut off within 15 minutes of activation. Intent to suspend issued 24)
#22 · Premises: emergency telephone provided −6
Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leaky valve near spa heat exchanger. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Jan 11, 2022 6 demerits · 2 violations
Inspector comments: Inspection conducted by Naly Lor under supervision of Heather Misenheimer. CPO was not present during inspection. Suggest to have a second CPO on site to check on the pool daily.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no weekly records of total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no visible air gap. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Dec 16, 2021 6 demerits · 1 violation
Inspector comments: Inspection conducted with Steve Hoyt. Due to COVID-19 precautions, inspection not signed by maintenance. Label not observed on both pumps. Verified Sta-Rite pump with 2 HP motor. Observed bromine tablets in the skimmer. G.S. 130A-2(3) Disinfectants shall be safely applied to the spa per manufacturer's instructions. In this case through the brominator. Observed one the screws loose on the main drain. Two other screws tightly securing the drain cover. Ensure that screws are securely installed. Failure to fully install all screws by next inspection will result in an immediate suspension. Rock in skimmer basket. Use only NSF approved skimmers and weighted skimmers. Heavy foam when jets were on. Recommend backwashing the filter, adding enzymes to the filter to break up oils, or draining and refilling the spa. Liquid acid stored in buckets labeled as containing bromine. Ensure chemicals are properly stored in properly labeled containers. Immediate suspension issued. G.S. 130A-2(3) Scheduled to reinspect tomorrow at 8:00 AM.
#22 · Premises: emergency telephone provided −6
Incorrect dialing instructions posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.

View this inspection on the county portal ›

Jan 20, 2021 0 demerits · 0 violations
Inspector comments: Inspection conducted with inspector Rachel Santimaw and pool operator Steve. Due to COVID-19 precautions, inspection was not signed by the operator. Equalizer line cover expires April, 25 2021. Replace with APSP-16 2017 approved covers or abandon the equalizer lines per state guidelines. Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve. Spa jets down for repairs. Did not test that jets shut off within 15 minutes of timer activation. Ensure this is tested prior to re-enabling the spa timer. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 17, 2020 22 demerits · 6 violations
Inspector comments: Inspection conducted with maintenance regional Matt Steller. Due to COVID-19 precautions, inspection was not signed by the operator. New pump motors installed for spa jet and spa filtration pumps, electrical permits obtained. E3709698 passed 7-7-2020, E3837930 passed 10-2-2020. Emergency call back goes to the front desk. Ensure that front desk is always attended or reroute emergency phone call backs to the emergency phone. Permits posted are expired. Go to Meckpools.Charmeck.org to print current permits and post in the pool area. Equalizer line cover expires April 25, 2021. Replace with APSP-16 2017 approved cover or abandon the equalizer line per state guidelines. Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve. Much of the spa plaster has eroded away, leaving mostly Pebbletec aggregate behind, surface very rough. Surface is brown, and appears to be too dark now to meet requirements. Recommend replastering the spa. Ensure that new plaster meets .2514 and is of white or light colored material. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.” Intent to suspend issued 5)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main drain partially pulled away from the spa step. .2537(7) Drain covers shall be in good condition and securely attached. Corrected by operator, damage screw replaced.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color tile missing. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not observed. .2518(e) Provide a spare basket for pump.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak near spa filter. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals stored in the pump room..2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Liquid acid for automatic feeder stored in a bucket labeled as containing bromine. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms 120F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 25, 2020 6 demerits · 1 violation
Inspector comments: Observed new pump motor not connected to electrical. An electrical inspection is required when pump electrical is disconnected or pump motors are changed. After reattaching power the spa must remain closed until an approved electrical inspection has been completed.
#3 · Water quality: pool water pH −6
Observed pH at 7.0 corrected to 7.6 during inspection. .2535(1) Maintain pH at 7.2 to 7.8.

View this inspection on the county portal ›

Nov 5, 2019 22 demerits · 6 violations
#2 · Water quality: disinfectant residual provided by −6
Spa Bromine at .4 ppm. Corrected to 4.0 ppm during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Total alkalinity not recorded weekly. Missing some weeks. Record weekly.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form for spa filtration indicates 1.5 hp pump. Actual pump 2 hp pump. Corrected PDSC form provided during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Valve from piping from heater leaking. Pump room floor wet. Repair leak and keep floor dry.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE1015. Does not meet rule of .2512. If ever replaced, replace with approved check valve.

View this inspection on the county portal ›

Jan 14, 2019 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water leaking from pump. Repair leak.

View this inspection on the county portal ›

Nov 19, 2018 6 demerits · 1 violation
#2 · Water quality: disinfectant residual provided by −6
Observed pH at 7.0. Corrected on site to 7.4.

View this inspection on the county portal ›

Feb 5, 2018 14 demerits · 4 violations
Inspector comments: Underwater light on spa not functioning. Recommend providing functional underwater lighting for spa. Screws on some of the main drains do not appear to be stainless steel screws. Insure that main drains are installed per manufacturer's instructions with stainless steel screws. Intent to suspend issued. 17) 24)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir not installed. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Loose deck tile by skimmer. Securely install tiles.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter installed between the pump and the filter. Install flow meter on the filtered water light per manufacturer's instructions. Recommend installing after the heater. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room. Provide either forced air or cross ventilation in chemical storage room. Recommend adding lighting to chemical storage room. Dry chemicals stored on the ground. Corrected by operator.

View this inspection on the county portal ›

Oct 23, 2017 6 demerits · 2 violations
Inspector comments: Filtration pump motor recently changed to a 2 HP motor, pump appears to be the same pump. Current permit not posted. Permits are available at Meckpools.Charmeck.org. Permit has been attached to this inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No ventilation in chemical storage room. Provide either continuous forced air or cross ventilation.

View this inspection on the county portal ›

Mar 21, 2017 4 demerits · 1 violation
Inspector comments: 0BSERVED DAILY AND WEEKLY CHECKS BEING RECORDED, BUT WITHOUT SPECIFIC NOTATION OF DAILY MAIN DRAIN CHECKS. THIS MUST BE DONE AND RECORDED EVERY DAY THE SPA IS OPEN. ALLEN EBY
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
OBSERVED FLOW METER TO BE NON-FUNCTIONAL. REPAIR THE FLOW METER.

View this inspection on the county portal ›

Nov 29, 2016 10 demerits · 2 violations
Inspector comments: Observed SDX Retro replaced with Aquastar A10RCFxxx on EQ line cover. PDSC submitted on-site.
#22 · Premises: emergency telephone provided −6
Observed 911 phone non-functional. Phone was replaced. -CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.

View this inspection on the county portal ›

Jan 20, 2016 14 demerits · 3 violations
Inspector comments: Observed pump doesn't match submitted PDSC sheet. Submit new correct PDSC sheet to Katie Wilson at MCHD
#3 · Water quality: pool water pH −6
Observed pH to be 7.1. pH 7.2-7.8 is required. CDI corrected to 7.3.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed all records properly kept except alkalinity not kept weekly. Alkalinity must be kept 1 time a week at least.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.

View this inspection on the county portal ›

Sep 25, 2015 0 demerits · 0 violations
Inspector comments: Spa was found to have correct pH an Br2 levels. Spa may re-open for swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Sep 24, 2015 6 demerits · 1 violation
Inspector comments: POOL WAS CLOSED TO SWIMMINGCFE 9/28/15
#3 · Water quality: pool water pH −6
Observed pH to be >8.4. pH shall be 7.2-7.8

View this inspection on the county portal ›

Feb 11, 2015 12 demerits · 3 violations
Inspector comments: Intent to suspend issued for # 8
#4 · Water quality: water temperature of heated pool −6
Observed pH at 8.1. Adjusted onsite to 8.3.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed weir missing in skimmer. Replace missing weir.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 117 degrees. Hot water in restrooms should not exceed 110 degrees.

View this inspection on the county portal ›

Oct 15, 2014 14 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pitting and some damage to spa walls and floor. Keep pool surface in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump leaking in pump room. Repair pump. Intent to Suspend issued.Recirucation lines for spa and pool connected. Systems must be separate of each other. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leaking pump. Keep dry. No cross/forced ventilation in chemical storage room and no lighting. Provide adequate lighting and cross/forced continuous ventilation.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Lines on recirucluation from main drain and skimmers not labeled in pump room. Clearly identify all pipes by color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >113 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Mar 24, 2014 18 demerits · 4 violations
Inspector comments: Intent to suspend issued.8)21)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Spa missing weir for skimmer. Install functional weir.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one inlet fitting. Install.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Underwater light does not appear to be securely attached. Screw observed on spa bench, possibly from light. Install light securely.
#22 · Premises: emergency telephone provided −6
Signage for emergency phone not visible from phone. Corrected.

View this inspection on the county portal ›

Mar 12, 2014 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
PH OFF SCALE; CORRECTED TO 7.2 DURING INSPECTION

View this inspection on the county portal ›

Sep 11, 2013 6 demerits · 2 violations
Inspector comments: Permit not posted - must be visible on pool deck. Found at meckpools.charmeck.org
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed build-up in skimmer under basket. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross/forced ventilation in pump room. Provide adequate ventilation.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DRURY INN & SUITES SPA” or State ID 2060550095). Inspection type (routine vs. follow-up) is not published in the county's data.