HILTON GARDEN INN AYRSLEY

1920 AYRSLEY TOWN BLVD, Charlotte, NC 28273
Year-Round Spa · NC permit/State ID 2060550156
Latest result20 demerits
Last inspectedFeb 23, 2026
Inspections on record23
On record sinceOct 7, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02346 Oct 7, 2013: 10Jan 28, 2014: 22Nov 26, 2014: 20May 28, 2015: 22Dec 2, 2015: 30Jun 21, 2016: 12Dec 6, 2016: 26Jun 26, 2017: 10Nov 21, 2017: 24Jan 19, 2018: 14Nov 6, 2018: 12Jan 29, 2019: 18Nov 15, 2019: 30Jan 13, 2020: 16Oct 20, 2020: 26Jan 7, 2021: 24Feb 21, 2023: 10Oct 17, 2023: 46Jan 18, 2024: 8Sep 23, 2024: 34May 8, 2025: 8Nov 5, 2025: 8Feb 23, 2026: 20
Oct 7, 2013Lower is betterFeb 23, 2026

Inspections & violations

Feb 23, 2026 20 demerits · 4 violations
Inspector comments: Issued Intent to Suspend (ITS) for fitting missing and records. Correct and contact Marie Daley at 704-507-6806 to lift ITS “W” ITS status Inspection with Ron Pauling Permit Restrictions: 1) Filtration - Flow meter must remain operable with flow from 49 gpm to 55 gpm to meet turnover and flow restriction of the skimmer. Flow greater than 100 gpm exceeds the main drains. Suction Hazard. 2) Feature - Flow meter shall remain operable with flow no greater than 100 gpm due to flow restriction of the drain cover. Suction Hazard. Looking into pipe used for plumbing
#3 · Water quality: pool water pH −6
Observed pH at 7.0. .2335 Maintain pH between 7.2- 7.8. Operator corrected to 7.2.
#4 · Water quality: water temperature of heated pool −6
Spa temperature 104.5 F at time of inspection. .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below. Operator turned heat down and corrected to 102.5 F.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records have out of range pH for multiple days with no maintenance correction or closure. Missing weekly alkalinty. Temperature not accurate on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked alkalinty and corrected. *permit item
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Inlet fitting missing and hole in wall (unsure of correct fitting) needs to be corrected with correct fitting (after identifying) .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *Permit item

View this inspection on the county portal ›

Nov 5, 2025 8 demerits · 2 violations
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Maintain pH between 7.2- 7.8. Corrected onsite. .2535(1) Maintain pH at 7.2 to 7.8.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 115 degrees. Hot water should not exceed 110 degrees in restrooms. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

May 8, 2025 8 demerits · 3 violations
Inspector comments: Lifted suspension for water quality and conducted inspection. FlowVis installed, hard to read. Permit restriction of no greater than 55 gpm (+/-) 5%, starts at 70 gpm, reads less than this, about 60 gpm. Timer could not be verified on jet pump. Feature pump exceeds drain cover flow. Requires a true flow reading and submittal of new PDSC form with flow reading for approval. Flow shall not exceed 100 gpm. Current piping does not appear to have the required 11" for FlowVis or other types of flow meter. A properly installed flow meter accurate to 5%-10% shall be installed. Pool may open without the jets functional. Currently turned off in pump room. Issued local permit sticker. Permit restriction that jets must remain inoperable until drain cover issue is addressed. “A” Open for Business
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors propped open onto pool/spa deck at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching and be closed when not in use. Closed and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water. Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Inadequate ventilation in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms over 110 F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Sep 23, 2024 34 demerits · 9 violations
Inspector comments: Inspection conducted with CPO Ron Pauling. Emergency phone calls back to front desk. Ensure front desk is staffed whenever the pool is open. New Pentair Superflo VST #342002 pump installed. .2510(b) Equipment replacement shall comply with Rules .2514 through .2524 and shall be approved by the Department prior to installation. - Immediate suspension item. Will need to submit in-field plan review application for approval. No electrical permit on file for newly installed pump. G.S. 130A-2(3) Electrical permit and passing inspection from Code Enforcement. There is an eyeball fitting below skimmer that does not seem to do anything. Ensure it is NOT tied to the skimmer equalizer line. If it is, it will need to be plugged per state guidelines. Emailed copy of In-Field Plan Review and Pool Drain Safety Data Compliance forms to the facility. Immediate suspension issued 6) .2510(b) Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
New pump installed than what was approved for this facility. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pile of sand on spa bench. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Spring-loaded equalizer line valve in skimmer. Ensure solid plugs on both ends of skimmer equalizer line. .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. - Intent to suspend item.
#14 · Pool maintenance: spa timer working properly −4
Spa timer running over 15 minutes. .2537(b) Spa times shall not exceed 15 minutes without manual resetting. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door to patio not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. Most spa piping PVC-DWV. .2518(d) Plastic pipe shall be a minimum of schedule 40 PVC. - Will follow up with facility.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water. Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Inadequate ventilation in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms 132.6F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Jan 18, 2024 8 demerits · 3 violations
Inspector comments: Lifted suspension and change to “A” Open for Business
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck at time of inspection. .2518(g) Keep flow meter operational. Operator adjusted and fixed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3’ clearance around equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water above 110 degrees F in restroom at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Oct 17, 2023 46 demerits · 11 violations
Inspector comments: Immediate suspension issued for water quality. Contact Marie Daley at 704- 507-6806 when in compliance to lift suspension. Spa must stay closed, with signage posted until suspension is lifted by Health Dept. Other permit items to verify at return visit include: records, fittings, timer and door onto pool deck Updated CPO to Amanda Kichton Inspection with Catie Johnson “E” Immediate Suspension
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine level of 0 ppm at time of inspection. .2535(5) Maintain chlorine at least 1.0 ppm. IMMEDIATE SUSPENSION ITEM.
#3 · Water quality: pool water pH −6
PH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not being kept at time of inspection.Test kit not available at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. *permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of visit. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Inlet fittings missing and hole in wall (unsure of correct fitting) needs to be corrected with correct fitting (after identifying) .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *Permit item
#14 · Pool maintenance: spa timer working properly −4
Spa timer running over 15 minutes. .2537(b) Spa times shall not exceed 15 minutes without manual resetting. *Permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door into pool stays open when opened all the way. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 4’ of spa. .2522(d) Provide at least four ft of clear walking space halfway around spa at all times. Operator moved and corrected.
#22 · Premises: emergency telephone provided −6
Placed on immediate hold from front desk when emergency phone called back. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Manager educating staff on answering and monitoring emergency calls. Corrected through education.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed standing water in pump room floor from spa leak. .2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water above 110 degrees F in restroom at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 21, 2023 10 demerits · 3 violations
Inspector comments: Issued permit for 2022/2023 season. Contrasting color bands have been corrected with paint, if future work is done, ensure it meets code. Timer has been adjusted. Doors self-closing and alarm installed at gym door. No propping doors open.
#3 · Water quality: pool water pH −6
PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator had just added acid before inspection due to high pH. PH adjusted to 7.2. Corrected. CPO is keeping spa closed until full circulation/turnover of chemicals and stable reading before opening.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed standing water in pump room floor from spa leak. .2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water above 110 degrees F in restroom at time of inspection. No toilet paper in women’s restroom. .2526(i) Water in restrooms shall not exceed 110 F. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Jan 7, 2021 24 demerits · 6 violations
Inspector comments: ITEMS THAT MAY WARRANT AN INTENT TO SUSPEND PERMIT: - Weirs must be present at all skimmers **Please ensure spa records are accurately kept, with pH, bromine, temperature, and main drain daily. Total akylinity checked weekly. Stacie Rhea present at time of inspection. Please contact EHS when ready to have suspension lifted, (704)-371-1589.
#2 · Water quality: disinfectant residual provided by −6
.2535(5) Maintain bromine at least 2.0 ppm. Observed bromine level at 0ppm at time of inspection. CDI: CPO corrected bromine levels. Spa now reads 2.0ppm.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of 8.0 at time of inspection. CDI: CPO corrected pH levels. Spa now reads 7.4.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed walls at water line stained with gray film.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weir. MAY WARRANT INTENT TO SUSPEND.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in pump room floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Observed hot water in men's restroom at 129F and women's restroom 114F.

View this inspection on the county portal ›

Oct 20, 2020 26 demerits · 6 violations
Inspector comments: Immediate Suspension for emergency phone and water quality. "E" Immediate Suspension status 30 Day Intent to Suspend (ITS) item: records. Will verify timer on return visit. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. No signature due to COVID-19. Inspection with Marisse Kennedy Report to Marisse Kennedy
#2 · Water quality: disinfectant residual provided by −6
Bromine test bleached out test kit. Turned purple/black on high strength test kit. G.S. 130A-2(3) Imminent Hazard to public. Lower to measurable level. **Immediate suspension item. Spa must REMAIN CLOSED until corrected. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#3 · Water quality: pool water pH −6
pH turned blue on test kit, not measurable. .2535(1) Maintain pH at 7.2 to 7.8. **Immediate suspension item. Spa must REMAIN CLOSED until corrected. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing for day of inspection. Pool had been closed previously. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. *permit item. Will verify on return visit
#22 · Premises: emergency telephone provided −6
At time of visit, emergency phone did not have address listed at local 911 and wrong telephone number. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. **Immediate suspension item. Spa must REMAIN CLOSED until corrected. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on pump room floor from hose running at time of inspection. .2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 126 degrees F in restroom at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Jan 13, 2020 16 demerits · 5 violations
Inspector comments: ITS for records, weirs, flow meter. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. Main drains (2 Aquastar A8R101, 2 Paramount SDX Retro) expire March 2020. Submit updated PDSC form for approval and replace prior to expiration to avoid permit suspension. Permit will NOT be issued for 2020 without replacement. Operator stated electrician repaired pump wiring noted in last visit. Advised electrical permits from Code Enforcement are required for electrical work. Did not observe hazard or change at time of visit. General Comment: 14) Spa timer reading over 15 minutes when turned on (18:36 on timer), but jets not staying on or working properly. Ensure repair of this item meets the rule: .2537 A timer switch that allows no more than 15 minutes of operation without manual resetting shall be used to control air blowers and hydrotherapy pumps on heated spas.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records available for spa (only pool) at time of inspection. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *30 Day ITS item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir for only skimmer missing at time of inspection. .2518(k) Replace missing weirs. *30 Day ITS item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck attime of inspection. .2518(g) Keep flow meter operational. *30 Day ITS item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Standing water under spa equipment in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Spa pump and some labels, mislabeled with "pool pump" labels. .2518(d) Piping and valves shall be labeled with color codes or labels.

View this inspection on the county portal ›

Nov 15, 2019 30 demerits · 7 violations
Inspector comments: Observed electrical conduit for spa filtration pump not secure to pump motor. Facility agreed to remain voluntarily closed until electrical work is complete. Work should be completed by a certified electrician and be inspected by MC Code Enforcement (980 314-CODE) Immediate suspension issued for pH, and main drain screws rusted. Call Chris Sells when repairs are complete at 704 576 8678.
#3 · Water quality: pool water pH −6
Observed pH below 6.8 during inspection. .2535(1) Maintain pH at 7.2 to 7.8.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed main drain screws rusted. .2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed eye fitting missing on return next to light. Observed one loose jet fitting on wall with skimmer. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#14 · Pool maintenance: spa timer working properly −4
Observed spa timer exceeding 15 minutes. Corrected during inspection. .2537(b) Spa times shall not exceed 15 minutes without manual resetting.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door from excersice room not self latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed sand filter leaking .2519 Keep filter in good repair. Observed flow meter not functiooing. .2518(g) Keep flow meter operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restroom at womans hand sin at 127F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Jan 29, 2019 18 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Bromine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Over 20 ppm bromine *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when correctd to lift suspension. Pool may not re open until suspension lifted by EHS*
#3 · Water quality: pool water pH −6
pH 6.8 at the time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when correctd to lift suspension. Pool may not re open until suspension lifted by EHS*
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no main drain checks on records. Some days missing on records and records not matching water quality at time of inspection. Operator added drain column to records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Handsink water in mens restroom above 110 F .2626(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Nov 6, 2018 12 demerits · 4 violations
Inspector comments: ITS for pump leak, spare pump basket and timer.
#14 · Pool maintenance: spa timer working properly −4
.2537(b) Spa timers shall not exceed 15 minutes without manual resetting. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Pump leaking. .2518(e) Provide a spare basket for pump. **30 Day Intent to Suspend items. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Jan 19, 2018 14 demerits · 5 violations
Inspector comments: Pool permit not posted. Keep posted in visible location. If spa is closed, "Pool/Spa Closed" sign must be posted.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Inconsistent/missing records with no corrective actions/maintenance for water quality out of range. Maintain daily records of pH, bromine (disinfectant residual), main drain checks, temperature and activities pertaining to pool maintenance and weekly TA and CA. Operator is going to train staff on record keeping and water quality testing. Contact Marie Daley at marie.daley@mecklenburgcountync.gov or 704-507-6806 with any questions and when issue is resolved.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from hallway into gym area (then into pool area) not self-closing, self-latching at time of inspection. Ensure doors self-close, self-latch or have audible alrm. Opertor adjusted door on left to remain closed so right door would work properly to self-close, self-latch. Also, main door propped open at time of inspection. Keep closed. Operator closed. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Spa pump leaking. Repair and keep pump room free of standing water.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Pipes not clearly identified. Exposed pipes and vavles shall be identified by a color code or labels. Work has been done on spa pump/piping. No label on pump. Recommended providing pump tag for identification.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water reaching 117 degrees F in restroom. Maintain hot water at 110 degrees F and below.

View this inspection on the county portal ›

Nov 21, 2017 24 demerits · 6 violations
#2 · Water quality: disinfectant residual provided by −6
Bromine 0.4 ppm. Maintain bromine at least 2 ppm.Corrected to 4 ppm bromine
#3 · Water quality: pool water pH −6
pH 8.0 at time of inspection. Maintain between 7.2 and 7.8. Operator corrected to 7.6.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records since 11/5. Maintain daily records of pH, bromine (disinfectant residual), main drain checks, temperature and activities pertaining to pool maintenance and weekly TA and CA.
#14 · Pool maintenance: spa timer working properly −4
Spa jets/timer not working at time of inspection. Keep in good repair and do not exceed 15 minutes when repaired.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Spa pump leaking. Repair and keep pump room free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water over 117 degrees F. Maintain hot water 110 degrees F and below.

View this inspection on the county portal ›

Jun 26, 2017 10 demerits · 3 violations
Inspector comments: Intent to Suspend issued for item 5. You have 30 days to reach compliance or permit will be suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drains are not being checked daily. TA and CA are not being checked. Check main drains daily and TA and CA weekly. ITS issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at pump for spa. No cross ventilation.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs too close to pool edge. Maintain 6 ft of clearance.

View this inspection on the county portal ›

Dec 6, 2016 26 demerits · 7 violations
Inspector comments: Immediate Suspension issued for #6.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain check entries at all on spa record. No chlorine, pH or water temperature entries in spa record since 11/29/16. ** Maintain complete spa records. See .2535 (11)
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
VGB information on PDSC forms approved by the MCHD (spa jet 6/2/15 & spa filtration 3/19/15) are no longer correct. Observed 2 Paramount SDX Retro covers on front of spa bench & 2 Aquastar covers on spa floor (both appear to be model A8Rxxx). ** Have pool professional complete new PDSC forms & submit to K. Wilson (MCHD) for approval. Immediate Suspension.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed scum on spa wall tiles. ** Clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir cemented down and unable to float/ function. ** Correct.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
-- No natural cross draft or forced air ventilation in equipment room or chemical room. -- No light in chemical room. --Equipment room floor wet under spa circulation piping. ** Identify water source point & resolve.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Hot water at least 135F at lavatories in restrooms. ** Maximum allowed is 110F.

View this inspection on the county portal ›

Jun 21, 2016 12 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No spa entries since 6/16/16. No total alkalinity readings for this month. ** Maintain complete spa records for every day the spa is open. Check & record total alkalinity at least 1 time per week. Log entries made today 6/21/16.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed scum on spa wall tiles. ** Clean. Spa floor & walls chipped. ** CPO reports that spa is going to be re-surfaced in ~1 month. Spa floor & walls appear to have some algae. ** Clean.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment room floor wet due to leak at spa circulation pump. ** Resolve. No natural cross draft or forced air ventilation in equipment room or in chemical room. No light in chemical room. Liquid chlorine stored in equipment room. ** See .2533 & .2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water at least 124.7F in restrooms. ** Maximum is 110F.

View this inspection on the county portal ›

Dec 2, 2015 30 demerits · 7 violations
Inspector comments: Immediate suspension issued.3)6)Contact Will Harrison (704-507-6824) when issues corrected for reinspection.
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.3ppm, adjusted to 0.7. Maintain at least 1ppm free chlorine. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records observed after June 2015. Check daily Cl, pH, Main drains and temperature. Check at least weekly Total Alkalinity. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed drain cover that was not listed on PDSC form on spa wall. Submit updated PDSC form and get approval from Health Department. - Immediate suspension item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Mold growing in skimmer. Maintain chemicals and clean as needed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One of the doors to outside patio not self-latching. Make doors self-closing and self-latching. If door to remain as is so that guests can get back inside during operating hours, make gates on patio self-closing and self-latching with a latch height of at least 54". - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.

View this inspection on the county portal ›

May 28, 2015 22 demerits · 6 violations
Inspector comments: i#6 One SDX Retro jet cover has been cut some so that it can fit beside spa step. ** Install an approved smaller jet cover. New PDSC form must be submitted & approved. CPO made arrangements with Caribbean Pools while EHS on-site to correct by the beginning of next week at the latest. Notify L. Boyes @ 704-507-6806.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spa water temperature being recorded every 5-6 days. ** Record daily.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
2 jet inlet fittings are missing components. ** Correct. Grate fitting on inlet (from circulation system) located immediately beside equilizer line cover. ** Install proper inlet cover if possible. Any change in the equalizer line cover must be approved through submission & approval of a new PDSC form.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair ~3' spa edge. ** Maintain 4' of clear walking space.
#22 · Premises: emergency telephone provided −6
Phone automatically dials 911 when handset lifted. Incorrect dialing instructions posted. ** Corrected while on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room does not have a light. ** Room should have a light fixture. Chlorine & muriatic acid drums stored in equipment room. ** Chemical room too small to accomodate.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 135.2F at lavatories in restrooms. ** Turn water temperature down. Maximum allowed is 110F.

View this inspection on the county portal ›

Nov 26, 2014 20 demerits · 6 violations
Inspector comments: #8 Observed disposable cup, hair & garbage in skimmer. **corrected during inspection. Intent to Suspend issued for #5 & #14. Note: EHS gave MCHD spa/ record form to be started today with required entries.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No written records of water quality available to review. **Maintain spa records @ spa site for daily & weekly entries and for review. Intent to Suspend. Intent to Suspend
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed grate fitting on water inlet (from circulation system). **install proper "eye" inlet fitting. Observed that 2 (of 8) jet inlet fittings are missing. **install.
#14 · Pool maintenance: spa timer working properly −4
Spa timer ran for ~20 minutes. **maximum allowed is 15 minutes. Correct. Intent to Suspend.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed that flow meter float is stuck. **resolve.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed a lot of water on floor @ spa circulation system. **Find source of leak & resolve to keep equipment room dry. Observed that chemical room does not have a light. **room/ closet should have its own light fixture.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water @ 136.9F @ lavatories in restrooms (off pool deck). **Lower hot water temperature - maximum temperautre allowed is 110F.

View this inspection on the county portal ›

Jan 28, 2014 22 demerits · 6 violations
Inspector comments: Intent to Suspend issued for #14. Post permit visible on pool deck.
#3 · Water quality: pool water pH −6
Observed pH at 8.2. Corrected to 7.4.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed two return/jets missing eyeball fitting. Replace.
#14 · Pool maintenance: spa timer working properly −4
Observed spa timer >15 minutes. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump leaking . Repair leak. Flow meter on return line from spa.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet and bicarb on floor. Chemicals stored in pump room. Keep floor dry and chemicals up off floor. Provide separate storage (built in 2008) for chemicals.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water >120 F in restrooms. Maintain at 110 F or below.

View this inspection on the county portal ›

Oct 7, 2013 10 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Adjusted onsite to 7.6.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room floor. Repair leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 130 degrees. Hot water should not exceed 110 degrees.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HILTON GARDEN INN AYRSLEY” or State ID 2060550156). Inspection type (routine vs. follow-up) is not published in the county's data.