‹ Back to search

0demerits

BARCLAY AT SOUTHPARK, THE

4801 BARCLAY DOWNS DR, Charlotte, NC 28210
Year-Round Spa · NC permit/State ID 2060550199
Latest result0 demerits
Last inspectedAug 3, 2026
Inspections on record13
On record sinceDec 29, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Dec 29, 2020: 14Mar 16, 2021: 4Jul 19, 2021: 12Jan 6, 2022: 4Sep 16, 2022: 0Feb 1, 2023: 2Oct 3, 2023: 18Jan 10, 2024: 4Nov 14, 2024: 4Jan 16, 2025: 0Oct 21, 2025: 12Jan 28, 2026: 0Aug 3, 2026: 0
Dec 29, 2020Lower is betterAug 3, 2026

Inspections & violations

Aug 3, 2026 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO Anna Eagle. All items in compliance. Spa remains in good standing and on A status. Drain covers - Filtration expires - 8/13/2030 - Feature expires - 1/8/2031 SALT IS NOT APPROVED Const. Date: 9/1/2020

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jan 28, 2026 0 demerits · 0 violations
Inspector comments: Salt not approved as primary chlorination.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 21, 2025 12 demerits · 3 violations
Inspector comments: Jet pump is not approved PDSC. Must remain OFF at all times. Pipe is 6” under drain covers with less than 4 inches from pipe distance to wall. Current installation and PDSC form is NOT APPROVED for jet pump. Piping in pump room from main drains for jet system is 6”. New covers must meet current federal Code for VGBA. If spa operates with jets on without approval of PDSC the permit will be suspended immediately. Salt not approved as primary Issued 30 Day Intent to Suspend (ITS) for feeder. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS “W” ITS status Inspection with Anna Eagle
#4 · Water quality: water temperature of heated pool −6
Spa water over 104 F at time of inspection. .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below. Operator adjusted to 102.9 and corrected.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Automatic feeders not shutting off with pump. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. *Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water on pump room floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in storage room adjacent to pool deck instead of in designated chemcial storage room.

View this inspection on the county portal ›

Jan 16, 2025 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Anna Eagle. Pool remains in good standing and on A status. All items in compliance. Note: Drain covers expire September 2025

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 14, 2024 4 demerits · 1 violation
Inspector comments: Conducted inspection with CPO Anna and EHS Casey. Intent to suspend issued for spa timer.
#14 · Pool maintenance: spa timer working properly −4
.2537(b) Spa times shall not exceed 15 minutes without manual resetting. Spa ran for 20 minutes without automatically shutting off. Intent to suspend item.

View this inspection on the county portal ›

Jan 10, 2024 4 demerits · 1 violation
Inspector comments: .2537(b) Spa times shall not exceed 15 minutes without manual resetting. Spa ran for over 45 minutes without automatically shutting off. CPO had to manually shut off spa. Intent to suspend item. Item must be corrected within 30 days or permit may be suspended.
#14 · Pool maintenance: spa timer working properly −4
.2537(b) Spa times shall not exceed 15 minutes without manual resetting. Spa ran for over 45 minutes without automatically shutting off. CPO had to manually shut off spa. Intent to suspend item.

View this inspection on the county portal ›

Oct 3, 2023 18 demerits · 5 violations
Inspector comments: Inspection conducted with Edward Irizary. Immediate suspension of permit issued due to no disinfection in pool - chlorine at 0.0 ppm. Spa closed with signs posted during inspection. Call Hope McIntosh at 980-229-7549 once pool chemistry is in compliance. Once suspension is lifted, a 30 day intent to suspend the permit may be issued for inoperable flow meter and for missing/incomplete records.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine at 0.0 ppm. Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Only digital records available for September and October 2023 - these digital records do not have recorded water temperatures or main drain checks. Records indicate that since July 2023, repeated pH values in both pool and spa below 7.2 with no corrective action or pool closure status noted. When pool chemistry is non-compliant, the operator must make necessary corrections and close pool as appropriate. *permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water on pump room floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in storage room adjacent to pool deck instead of in designated chemcial storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Hot water in both mens and womens restrooms greater than 110f. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Soap dispensers ceramic - unable to determine if shatterproof material. Ensure soap dispensers are made of shatterproof materials.

View this inspection on the county portal ›

Feb 1, 2023 2 demerits · 1 violation
Inspector comments: Inspection conducted with Edward Irizarry and Oscar Rivero. Note: Heavy salt buildup on pump room equipment. Pool is moving away from use of salt. Remove buildup to prevent corrosion of pump room equipment.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water on pump room floor.

View this inspection on the county portal ›

Sep 16, 2022 0 demerits · 0 violations
Inspector comments: Inspection completed with Edward Irizarry present.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jan 6, 2022 4 demerits · 1 violation
Inspector comments: No signature due to COVID-19. Inspection completed with Anna Eagle and Juan Esquivel present. ITS issued for no records being maintained while pool was opened on weekends. Correct by 2/5/2022.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Observed pool records not being written on weekends. CPO, Anna Eagle indicated pool is opened to residents on weekends. Intent to suspend issued. Correct within 30 days.

View this inspection on the county portal ›

Jul 19, 2021 12 demerits · 2 violations
Inspector comments: Observed sand filter had blown gasket. A new one was ordered. No standing water .2519(b) - recommend replacing sand filter or call for service Inspection completed by Mia Lowery under supervision of Stacie Rhea
#3 · Water quality: pool water pH −6
Observed pH at 7.0 corrected during inspection to 7.2. Maintain pH at 7.2-7.8
#22 · Premises: emergency telephone provided −6
Observed no address sign w/ phone number by emergency phone. .2530 (b) Provide dialing instructions, address of poll location and telephone number. Corrected during inspection

View this inspection on the county portal ›

Mar 16, 2021 4 demerits · 1 violation
Inspector comments: Inspection completed with Anna (Wellness Director) and Mike Trofe present. No signature due to COVID-19.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records for pool water quality being kept on Saturdays and Sundays. If pool is open, records must be maintained daily. Intent to suspend permit issued. Correct by 4/15/2021.

View this inspection on the county portal ›

Dec 29, 2020 14 demerits · 5 violations
Inspector comments: Issued local permit sticker. Chaned to "A" Open for Business. Storage in pool area not approved for chemical storage. Must follow all Executive Orders for COVID-19. Post Max Occupancy and required signage (3 W's). Salt not approved as primary chlorination. No signature due to COVID-19. Inspection with Michael Trofe Report to MTrofe@libertyseniorliving.com
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Temperature missing from daily records check. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added temperature and corrected. Updating new logs to include temperature.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from men's locker room not self-latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Staff adjusted to self-latch, corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in storage room in pool area, on floor. Not permitted for chemical storage. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Operator is moving these chemicals and will not use this space for chemical storage.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Spa jet pump and piping not labeled in equipment room. All other piping labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms missing soap, paper towels and toilet paper. .2526(j) Provide soap and soap dispenser, no glass, at each sink. .2526(l) Provide toilet paper and dispensers in restrooms. Provide paper towels or hand drying in restrooms. Pool not in operation at time of inspection. Operator is supplying restrooms with supplies prior to opening.

View this inspection on the county portal ›