4demerits
PROVIDENCE ROW APARTMENTS II - SPA
5355 PINEHURST PARK DR, Charlotte, NC 28211
Year-Round Spa · NC permit/State ID 2060550207
Latest result4 demerits
Last inspectedApr 8, 2026
Inspections on record6
On record sinceSep 21, 2023
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 21, 2023Lower is betterApr 8, 2026
Inspections & violations
Apr 8, 2026 4 demerits · 1 violation
Inspector comments: Inspection completed with Jovany Rivera present.
Intent to suspend permit issued for inadequate record keeping on main drain safety checks and total alkalinity recordings. Correct within 30 days or permit may be suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed missing mains drain safety checks and total alkalinity checks for March, 2026. Intent to suspend permit issued.
Sep 9, 2025 4 demerits · 1 violation
Inspector comments: Inspection completed with Elbio Rosario present.
Permit conditions/restrictions:
1. No flow restrictions on feature pump.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 of 3 weirs missing. Replace.
Mar 27, 2025 8 demerits · 2 violations
Inspector comments: Inspection completed with Nick Jeffries in maintenance.
Intent to suspend permit issued for inadequate record keeping. Correct within 30 days or permit may be suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no main drain of temperature recordings being logged daily. Intent to suspend permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris inside skimmer basket rims.
Oct 15, 2024 14 demerits · 3 violations
Inspector comments: Inspection completed with Nick Teal present.
Correct audible ring back on phone when receiving incoming calls within 30 days.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.0. CDI- adjusted to 7.8.
#22 · Premises: emergency telephone provided −6
Phone must audibly ring when receiving incoming calls. Observed phone with faint ring back. Correct within 30 days or permit may be suspended.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed pump room not locked and accessible to public due to door not self latching when closed.
Feb 14, 2024 6 demerits · 1 violation
Inspector comments: Inspection completed by Jordan McClenic under supervision of Christopher Sells.
Observed main drain screws secured, pH controller recalibrated during inspection.
#3 · Water quality: pool water pH −6
Observed spa pH at 6.9. CDI - Corrected to 7.6 during the inspection.
Sep 21, 2023 10 demerits · 2 violations
Inspector comments: Onsite visit to pool with Angelo White, NW Ravin, for construction final. All items corrected. Construction final passed.
Two items to address prior to follow-up inspection.
1)Ensure all screws are secure in main drains. Some did not appear to be screwed in complete.
2)Calibrate automated feeder. Was reading 7.3 at time of inspection with spa pH at 7.0. Corrected during the inspection.
Note: Refrigerator glass verified as tempered during the site visit.
No permit restrictions on variable speed pumps.
Filtration Pentair Whisperflo, WFET-12, 3 hp pump with (2) VGBA-2017 Aquastar 914xxx drain covers. EQ lines plugged in skimmer.
Feature Pentair SuperfloVSF, 342002 with (2) VGBA-2017 Aquastar 914xxx drain covers.
Jets Pentair WhisperfloXF XFET-20, 5 hp pump with (2) VGBA-2017 Aquastar 1216xxx drain covers.
Operating permit issued for night swimming. A follow-up inspection will be completed within 30 days of permit issuance. Inspection will be unannounced.
#3 · Water quality: pool water pH −6
Spa pH at 7.0. Corrected to 7.6 during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. CPO had not yet taken over the spa. Log book sample page provided to operator. Ensure daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for cyanuric acid and total alkalinity.