SAUNA HOUSE CHARLOTTE - PUBLIC LARGE 5X13

1500 W MOREHEAD ST, UNIT H, Charlotte, NC 28208
Year-Round Spa · NC permit/State ID 2060550217
Latest result16 demerits
Last inspectedFeb 12, 2026
Inspections on record4
On record sinceJan 24, 2025

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Jan 24, 2025: 0Feb 18, 2025: 16Nov 20, 2025: 22Feb 12, 2026: 16
Jan 24, 2025Lower is betterFeb 12, 2026

Inspections & violations

Feb 12, 2026 16 demerits · 4 violations
Inspector comments: James Grogan present during the inspection. Intent to Suspend issued for: .2535 - repair leaks at chlorinator A return visit will be made in 30 days to verify completion of ITS items.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
One screw missing from flooring grate on pool floor. Flooring appears secure. Replace screw and keep flooring in good repair.
#22 · Premises: emergency telephone provided −6
Facility replaced emergency phone signage with labels on backside of phone. Address missing St. Corrected during inspection. Recommended that operator notify phone provider to add Ste H to location of pool. Operator contacted phone company while onsite. Emergency phone signage blocked by plant. Plant moved during the inspection.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Small leak at chlorinator at lid. Repeat non-compliance from previous inspection. Repair leak at chlorinator to ensure pump room floor is kept dry. Additional leak at chlorinator line. Repair leaks. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet in pump room due to leak at chlorinator. Keep pump room floor dry.

View this inspection on the county portal ›

Nov 20, 2025 22 demerits · 6 violations
Inspector comments: Caroline Evatt present during the inspection. PDSC form on file indicated (1) skimmer. Two skimmers installed. Adjusted on paperwork. Permit Restrictions: Flow meter must remain operable at 54 to 55 gpm to meet turnover and flow restriction of the suction pipe. Note: No placard on pump. Shows labeling of pump per PDSC form - not model listed. Model number matches what is listed on public small spa pump. All pumps are the same. Intent to Suspend issued for front door: .2528 - all doors shall self-close, self-latch or self-close, with audible alarm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some days missing logs for main drain checks. Ensure daily record keeping for main drains for covers on the spa wall. Did not warrant permit action/only missing several days over past months. Test reagent for DPD-1 discolored. Replaced during the inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Right door from inside building with audible alarm not operable. Door shall self-close, with audible alarm. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Skimmer lid not secure or flush with spa deck. Spacer installed that is not staying in place. Offset not >1/2". Repair so that deck is secure.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Small leak at chlorinator. Did not warrant repair at time of inspection. Repair leak at chlorinator to ensure pump room floor is kept dry.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter reading at 48 gpm. Operator turned up pump to meet permit restriction during inspection. Flow required at 54 gpm to 55 gpm. Written on pipes at time of inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Key kept in lock for pump room and equipment room. If not in use, door shall remain locked without key so inaccessible to the public. Pump room wet due to leak at public large. Algae growing on pump room floor. Keep clean/eliminate algae growth.

View this inspection on the county portal ›

Feb 18, 2025 16 demerits · 5 violations
Inspector comments: Intent to Suspend issued for back door. .2528 - repair door to self-close, self-latch. Brandon Grogan present during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drain checks not recorded daily. Record daily.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Tighten handrail so secure.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back door not closing when partially opened. Repair door to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damage to deck tile near wall (does not present hazard to public with offset or damage at time of inspection). Repair tile. If worsens or offset is >1/2", will require repair in the future.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet under chlorinator in pump room. Ensure no leaks. Keep floor dry.

View this inspection on the county portal ›

Jan 24, 2025 0 demerits · 0 violations
Inspector comments: Permit issued Permit restriction 1)Flow meter shall remain operable. Flow shall remain at 54 gpm to 55 gpm to meet turnover and flow restriction of the suction pipe. 2)Sump pump required to drain spa.

No violations were recorded for this inspection.

View this inspection on the county portal ›