12demerits
BEST WESTERN PLUS
13830 STATESVILLE RD, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500888
Latest result12 demerits
Last inspectedJul 17, 2026
Inspections on record10
On record sinceJun 3, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 3, 2014Lower is betterJul 17, 2026
Inspections & violations
Jul 17, 2026 12 demerits · 3 violations
Inspector comments: Permit Restriction - Flow must not exceed 100gpm.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets, except vacuum ports, shall be protected by anti-entrapment cover/grates in compliance with APSP-7/APSP-16. One equalizer cover missing CORRECTED
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Water level shall be maintained to assure skimmers are operable. Water near top of skimmer opening - Maintain in middle of opening.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Floor wet due to leaking backflow preventer - Repair.
Jul 7, 2026 24 demerits · 6 violations
Inspector comments: Permit Denied
Permit restriction:
Flow meter must remain operable. Flow shall not exceed 100 gpm due to drain cover flow restriction. Suction Hazard.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf material on pool floor
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Water level shall be maintained to assure skimmers are operable. Observed water level too low for skimmers to remain operable.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed footing missing from pool ladder
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed pool buoy not approved by USCG. Approval information was left with pool operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Observed deck chairs next to pool edge
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Observed pool motor turned off and flow meter not operational.
Jun 26, 2025 16 demerits · 6 violations
Inspector comments: Permit condition: Flow meter must remain operable. Flow shall not exceed 100 gpm due to drain cover flow restriction.
Night swimming not permitted
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed two weirs missing.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder missing foot cap.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed fan not working in pump room
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed no labeling on piping and valves.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(c) Floor drains shall be provided in restrooms. Observed no floor drain in restroom.
Aug 22, 2024 38 demerits · 11 violations
Inspector comments: Pre-permit inspection conducted with CPO Robin Vansickle and Charlie Vansickle.
Verified PDSC information and items from past visits.
Outer rope on ring buoy starting to fray. Recommend replacing with new US Coast Guard approved ring buoy before next pool season.
Emergency phone number calls back to front desk. Ensure someone is at the front desk whenever the pool is open.
New permit condition: Flow meter must remain operable. Flow shall not exceed 100 gpm due to drain cover flow restriction.
Permit issued
No Night Swimming
Paper permit will be posted on our website in 3-5 business days for your records.
#3 · Water quality: pool water pH −6
PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Only checking chlorine and pH. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Now using state log sheet, tested Total Alkalinity and Cyanuric Acid today.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing. .2518(k) Replace missing weir.
One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Ladder missing endcap. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy with new 60 foot throw rope. .2530(a) Provide USCG approved ring buoy. With attached 30 foot throw rope at least 1/4 inch in diameter. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
#18 · Premises: lifeguards present or warning signs posted −4
Warning - No Lifeguard on Duty sign missing. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Fan not working in chemical storage room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some labeling and arrows on piping worn off or missing. .2518(d) Piping and valves shall be labeled with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restroom 116.6 F. .2526(i) Water in restrooms shall not exceed 110 F.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bib not observed in restroom. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.
No floor drain in restroom. .2526(c) Floor drains shall be provided in restrooms.
May 7, 2019 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope to short by (4ft) CDI new buoy with correct length rope provided.
May 7, 2018 0 demerits · 0 violations
Inspector comments: No violations observed. Both equalizer lines have Aquastar 6HP covers on them and are not pulgged on the wall or in the skimmer.
No violations were recorded for this inspection.
Jun 26, 2017 20 demerits · 5 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
A couple times over the last two months the CA and TA were not checked weekly. Check and record TA and CA within 7 days of previous check.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir is stuck and not functional. Repair or replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy was in chemical room. Keep ring buoy and rope in pool area at all times unless the pool is closed.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Several chairs within 6 ft of pool edge. Maintain 6 ft of clearance on deck from pool edge.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
There is a leak at the chlorinator.
May 31, 2016 24 demerits · 5 violations
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Observed water cloudly; not able to clearly see bottom of pool. Immediate Suspension Issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope greater than 30ft. CDI PIC cut rope and tied; remeasured at 30ft.
#22 · Premises: emergency telephone provided −6
Observed emergency phone nonoperational. Immediate Suspension Issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water collecting on pump room floor. Observed ventilation in chemical room nonoperational.
Jun 8, 2015 18 demerits · 5 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no main drain or cyanuric acid checks on the pool record- provided today. Main drain must be checked daily and cyanuric and alkalinity must be checked weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed a loose ladder today.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed a throw rope that was >50' today- cut down to 30' to correct.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs and tables within 6' off the pool- moved to correct today.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on the pump room floor.Observed the chemical room fan not in operation today.
Jun 3, 2014 18 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed missing paint on pool floor. Repaint/touch-up paint by next swimming pool season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace missing weir in skimmer basket!
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Provide six feet clearance around pool deck. Today clearance around pool deck is three feet due to tables and chairs around pool deck.
#18 · Premises: lifeguards present or warning signs posted −4
Warning No Lifeguard on duty was posted at arrival of inspection. Warning No Lifeguard On Duty Sign found in pump room. Sign placed within swimming pool area at time of inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Repair shower on pool deck.
Permits at this address
Other permits for this place
Same name, separate permit (for example a pool, kitchen or lunchroom). Each is scored on its own.
- A97Best Western Plus-HuntersvilleLodging · Aug 2013 – Mar 2026 · 13 inspections
Matched by street address. Each permit has its own grade and history.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BEST WESTERN PLUS” or State ID 2060500888). Inspection type (routine vs. follow-up) is not published in the county's data.