‹ Back to search

6demerits

BEREWICK MANOR HOUSE

6615 BEREWICK COMMONS PKY, Charlotte, NC 28278
Seasonal Wading Pool · NC permit/State ID 2060510222
Latest result6 demerits
Last inspectedApr 30, 2026
Inspections on record14
On record sinceMay 8, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 May 8, 2014: 2May 6, 2015: 26Apr 27, 2016: 8May 4, 2017: 10Apr 18, 2018: 4May 3, 2019: 0Apr 21, 2020: 6Apr 15, 2021: 2Apr 19, 2022: 0Apr 5, 2023: 6Apr 17, 2023: 4May 2, 2024: 6Apr 16, 2025: 6Apr 30, 2026: 6
May 8, 2014Lower is betterApr 30, 2026

Inspections & violations

Apr 30, 2026 6 demerits · 1 violation
Inspector comments: NO NIGHT SWIMMING PERMITTED Main drain covers expire: 04/25/2029
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. EHS observed pH at 8.2. CDI- CPO was able to correct pH to 7.6. -6-

View this inspection on the county portal ›

Apr 16, 2025 6 demerits · 1 violation
Inspector comments: Night swimming not permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed ph at 7.0. CDI, ph corrected to 7.5 during inspection.

View this inspection on the county portal ›

May 2, 2024 6 demerits · 1 violation
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine’s measuring too low during inspection; CDI disinfectant corrected during inspection.

View this inspection on the county portal ›

Apr 17, 2023 4 demerits · 1 violation
Inspector comments: Baby pool will close at 8pm. Only main pool will be utilized for swim meets. Night swimming is prohibited.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves and other floating debris in pool. CDI: pool being cleaned during inspection.

View this inspection on the county portal ›

Apr 5, 2023 6 demerits · 1 violation
Inspector comments: Permit denial issued for violation 22 - 911 operator was not able to provide address for location of pool therefore would not be able to route services to pool in case of an emergency. Pool placed on Q status. Operator must call front office at 980-314-1620 and request a reinspection and $100 fee must be paid before EHS can make a visit to issue permit.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. 911 operator was not able to provide address for location of pool therefore would not be able to route services to pool in case of an emergency. Permit denied. Q status issued.

View this inspection on the county portal ›

Apr 19, 2022 0 demerits · 0 violations
Inspector comments: No violations noted at this time.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 15, 2021 2 demerits · 1 violation
Inspector comments: Covid 19 restrictions, no signature. Mike present during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof in restrooms.

View this inspection on the county portal ›

Apr 21, 2020 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in both mens and womens restrooms not shatterproof.

View this inspection on the county portal ›

May 3, 2019 0 demerits · 0 violations
Inspector comments: No violations during inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 18, 2018 4 demerits · 1 violation
Inspector comments: NIGHT SWIMMING IS NOT PERMITTED. LIFEGUARD IS NOT REQUIRED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Plastic cover for pipes in the form of a boulder located right outside fence. Boulder is less than 45 inches providing a foothold. Fence built prior to 2010.

View this inspection on the county portal ›

May 4, 2017 10 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
No suction hazard release system for main drains. Facility must provide Mecklenburg County with TDH forms.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Plastic cover for pipes in the form of a boulder located right outside fence. Boulder is less than 45 inches providing a foothold. Fence built prior to 2010.

View this inspection on the county portal ›

Apr 27, 2016 8 demerits · 4 violations
Inspector comments: WADING POOL PERMIT CANNOT BE ISSUED until a new PDSC form has been submitted & approved. (1 Sta-Rite pump has been replaced with a Hayward pump - feature.) (Note: CPO reports that gutter wading pool has surge tank.)
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced air ventilation in equipment & chemical rooms not working. ** Correct. Light bulbs burnt out in equipment room or features inoperable. ** Resolve.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash pipe turns down into sump. ** Provide complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One shower inoperable. No shower head. ** Rectify.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention on hose bib in equipment room. ** Install vacuum breaker.

View this inspection on the county portal ›

May 6, 2015 26 demerits · 9 violations
Inspector comments: Pre-permit inspection passed. Permit will not be issued until correct PDSC forms submitted. Three forms submitted with 4 pumps in pump room.6 main drains Sta-Rite PRA6G - 2 hpSta-Rite P6E6H - 3 hpSta-Rite PRA6F- 1.5 hpPentair - 5FEGiven 30 days to post sign in wading pool area of location of emergency phone.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log book not provided. Provide log book.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some cracking of plaster on pool floor. Keep in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence with 38" between horizontals. Maintain 45" between horizontals.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational. Flow meter replaced during inspection. Low flow so no reading. Flow meter must be operational by 2017 season. Operator stated they will replaced the multi-port. Pressure gauge not working. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights burnt out in pump room. Provide lighting. Pump room floor wet. Keep dry.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labeling on pipes not provided. Clearly identify all pipes with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restrooms. Provide soap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib on pool deck, in pump room and in women's restroom with no backflow prevention device. Provide backflow prevention device.

View this inspection on the county portal ›

May 8, 2014 2 demerits · 1 violation
Inspector comments: 33. No back flow device on exterior hose bib of main deck. Provide back flow device.Permit shall remain posted and visible upon entry to pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on the floor of the pump room. Repair drip of side access line.

View this inspection on the county portal ›

Permits at this address

Other permits for this place

Same name, separate permit (for example a pool, kitchen or lunchroom). Each is scored on its own.

Matched by street address. Each permit has its own grade and history.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BEREWICK MANOR HOUSE” or State ID 2060510222). Inspection type (routine vs. follow-up) is not published in the county's data.