2demerits
NORTHSTONE COUNTRY CLUB-FEATURE
15801 NORTHSTONE DR., Huntersville, NC 28078
Seasonal Wading Pool · NC permit/State ID 2060510154
Latest result2 demerits
Last inspectedMay 5, 2026
Inspections on record13
On record sinceMay 12, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 12, 2014Lower is betterMay 5, 2026
Inspections & violations
May 5, 2026 2 demerits · 1 violation
Inspector comments: Filtration pump shall remain at speed 3450 RMP to meet turnover. Filtration main drains expire 5/20/28. Feature main drains expire 4/1/29. Feature drains <36” apart unblockable drain covers SVRS installed but not required.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof.
Apr 25, 2025 4 demerits · 1 violation
Inspector comments: Permit issued.
Pool is not permitted for night swimming.
Unable to test Vac-Alert system for feature pump. However, the drain covers are 2 Aquastar WAV18WR. They are 18 inches wide in all directions and unblockable according to APSP standards.
Unable to determine flow to due flow meter that is unable to read properly.
Permit Restrictions: PUMP SHALL REMAIN AT SPEED SETTING 3450 RPM TO MEET TURNOVER.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. Observed flow meter on return line that is not capable of measuring 1.5 times the design flow. Flow meter measures to 120 GPM and is showing a flow reading that appears to exceed that flow rate. Install a proper flow meter.
.2518(g) Install flow meter on return line per manufacturer instructions. Observed a second flow meter that is not installed per manufacturer instructions. Install properly.
Aug 12, 2024 22 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Jeremy Laurer.
Some wall tiles missing. Prior to 2025 pool permit being issued, will need to replace missing wall tiles.
Permit condition that pump must be set at maximum speed, 3450 RPM to meet turnover. Observed pump set at 3000 RPM. - Corrected.
Pool with Vac-Alert SVRS. System must be tested at least monthly and recorded in log book. Recommend installing a valve on piping to make testing easier. CPO had to get in pool with rubber mat to test today.
Verified in-field plan review items:
4 skimmers plugged per state guidelines.
7 returns
Main drain, skimmer, return lines appear to be 4” piping.
Pentair TR140C Filter.
Permit issued.
No Night Swimming.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) Pools with single main drain or drains <36" apart shall provide a safety vacuum release system (SVRS) or other methods of preventing bather entrapment. Per ANSI/ASME A112.19.17, these must be must be tested monthly per manufacture’s instructions and documented. - Corrected. Operator tested today.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
3 sides of pool lined with lounge chairs. Only 3 feet of deck clearance. .2522 (c) Provide at least 4 ft clear walking space around wading pool at all times. - Corrected. Lounge chairs removed.
#18 · Premises: lifeguards present or warning signs posted −4
Warning - No Lifeguard on Duty signage heavily faded. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Eyeball fitting installed on vacuum line. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected. Eyeball fitting removed and self-closing vacuum cap installed.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
May 17, 2023 14 demerits · 3 violations
Inspector comments: NOTE: On site pre-permit inspection verification. Observed the Feature main drains, the distance between 2 set of drains is not at least 36” apart. The pump has a suction alter attached to it. PIC cannot verified or tested if the suction hazard is working properly.
PERMIT RESTRICTION:
THE FEATURE PUMP HAS TO REMAIN OFF (NOT IN USED AT ANY TIME) UNTIL THE SUCTION HAZARD HAS BEEN VERIFIED AND RESOLVED. The facility has one week (until 5/24/2023) to resolve the issue. David will call Ponpasert (704-617-9777) for verification. If issue is not resolved, permit action maybe taken.
David Johnson present during inspection.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Observed chlorine tablets in two of the skimmer baskets. Items was removed at the time of inspection, chlorination through the pump chlorinator. ENSURE TO CHLORINATE THE WADDING POOL THROUGH CHLORINATOR.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one broken weir, replaced a new one during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522 (c) Provide at least 4 ft clear walking space around wading pool at all times. Observed 2 ft apart between furnitures and edge of the pool. Furnitures removed to make room for walking space during the inspection.
May 11, 2022 8 demerits · 2 violations
Inspector comments: No night swimming permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir broken. Replace
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operating properly. Corrected during inspection.
May 17, 2021 6 demerits · 2 violations
Inspector comments: Night swimming NOT permitted.
Inspection completed with Jacob Wilks.
Report to 'Jacob Wilks'
No signature due to COVID-19.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. CDI: CPO emptied baskets.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed wet floor throughout various parts of pump room.
May 20, 2020 14 demerits · 4 violations
Inspector comments: Inspection conducted with Jacob Wilks. Due to COVID-19 precautions, inspection was not signed by the operator.
Incorrect skimmer lids installed. Install securely fitting skimmer lids designed to fit that skimmer model.
Note: Data plate on filtration pump states it is a Pentair Challenger CHII-NI-3FE pump, pump has been verified as a CHII-NI-1F pump. Observed 1 HP motor for pump.
Pressure guage reading < 5 PSI. .2519(k) Provide operational pressure gauge on filter.
Flow meter heavily worn, installed between two elbows. Recommend installing a new flow meter per manufacturer's instructions and capable of measuring within 10% of true flow.
Permit issued.
No night swimming.
“Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in
effect unless such Orders are rescinded or superseded by another applicable Order.”
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pool recently replastered, eyeball fittings installed on vacuum lines. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet from filters and chlorinator from other pumping systems leaking. .2533(d) Pump room floor shall be kept dry and free of standing water.
Chemical storage room used for general storage. Store only pool chemicals in the chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
May 22, 2019 12 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Pool has debris at bottom needing cleaning.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. Pool gate at 47". Corrected: PO lifted gate to 48".
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Hose bib outside guard room needs backflow prevention device.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Backwash pipe needs air gap from height of pit.
GENERAL COMMENT: Permit issued
Apr 19, 2018 16 demerits · 4 violations
#3 · Water quality: pool water pH −6
.2535 Maintain pool PH at (7.2-7.8) Observed pool PH measuring 6.8; Pool PH corrected to 7.4.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool floors kept clean; Observed debris on pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518, .2537 Keep skimmer system clean; Observed skimmer baskets having debris collected in need of cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533, .2534, .2537 Keep equipment room dry; Observed wet pump room.
Keep pump room in good repair; Observed damaged wall in pump room.
May 11, 2017 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Advised to keep skimmers clean.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction. Lounge chairs within 6' of pool edge. CDI - pool operator moved the lounge chairs back.
May 12, 2016 8 demerits · 2 violations
Inspector comments: Pool passed pre-inspection
Report received by Amanda Shore
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep 5' of clear walkway around pool perimeter
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working
Jun 1, 2015 8 demerits · 3 violations
Inspector comments: Observed contrasting bands on both steps more than 1" from edge.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chairs and metal tent within 3 feet of pool edge. Provide 4FT clearance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.Observed light/ventilation tied together. Provide continuous forced ventilation.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no back flow prevention on hose bib. Provide.
May 12, 2014 12 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool with debris. Clean the pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not functional. Corrected onsite.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room wet and chemical room light not functional. Keep pump room dry and repair light.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at back wash pit. Provide air gap.
Permits at this address
Other permits at this address
- A96Northstone Country Club KitchenRestaurant · Sep 2020 – Oct 2026 · 20 inspections
- A100Northstone Country Club Pool Concession StandFood Stands · Jul 2020 – Jul 2026 · 9 inspections
- 4demeritsNorthstone Country Club - Slide PoolSeasonal Swimming Pool · May 2015 – May 2026 · 13 inspections
- 4demeritsNorthstone Country Club-BackSeasonal Swimming Pool · May 2014 – May 2026 · 15 inspections
- 0demeritsNorthstone Country Club-MainSeasonal Swimming Pool · May 2014 – May 2026 · 14 inspections
Matched by street address. Each permit has its own grade and history; this is a shared address (for example a mall, airport, stadium, grocery store or food-truck base), so histories are not combined.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “NORTHSTONE COUNTRY CLUB-FEATURE” or State ID 2060510154). Inspection type (routine vs. follow-up) is not published in the county's data.